PLC s7 200 Thông số kỹ thuật và cách đấu dây

64 3.3K 2
PLC s7 200  Thông số kỹ thuật và cách đấu dây

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

PLC s7 200 Thông số kỹ thuật và cách đấu dây

General 2 CPUs 5 Digital expansion modules 19 Analog expansion modules 24 Communication modules 32 Power supplies 35 Human Machine Interface 36 SIMATIC Industrial Software 40 Configuring forms 46 Summary of ordering data 52 Appendix 56 s The products and systems described in this catalog are sold under application of a quality management system certified by DQS in accordance with DIN EN ISO 9001 (Certificate registration No.: 1323-03). The DQS Certificate is re- cognized in all EQ Net countries (Reg. No.: 1323). SIMATIC Micro PLC SIMATIC S7-200 Extract from Catalog ST 70 Edition September 2000 Supersedes: Extract SIMATIC S7-200 from Catalog ST 70, Edition August 1999 For further information contact your local Siemens representative The products listed in this catalog are also available from the CD-ROM Catalog CA 01. Order No.: E86060-D4001-A100-B4-7600 Page 2 Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 SIMATIC S7-200 General SIMATIC S7-200 ■ Overview •The micro PLC that offers maximum automation at minimum cost •Highly integrated, space- saving, powerful •Can be used both for simple controls and for complex automation tasks •In stand-alone mode, in networks and within distributed structures •Suitable for applications where programmable controllers would not have been viable in the past •W ith outstanding real-time performance and powerful communication (PPI, PROFIBUS-DP, AS- Interface) •Extremely simple installation, programming and operation ■ Application The SIMATIC ® S7-200 ® is a micro PLC for open-loop and closed-loop control tasks in mechanical engineering and plant engineering. It combines maximum automation with minimum cost. SIMATIC S7-200 applications range from replacing relays and contactors to handling complex automation tasks in stand-alone mode, in networks and within distributed configurations. To save costs, the S7-200 is increasingly being employed in areas that previously required special electronics. Applications include: •Baling presses •Plaster and cement mixers •Ventilation plants •Centralized/flange lubri- cating systems •W oodworking machinery •Gate controls •Hydraulic lifts •Conveyor systems •Food and beverage industry •Laboratories •Modem applications (remote monitoring) •Electrical installations The S7-200 features: •Easy to learn, with special starter packages and manuals •Uncomplicated operation; powerful, easy-to-use standard instructions and user-friendly programming software reduce programming to a minimum •Unequaled real-time features; interrupt functions, high-speed counters and pulse outputs permit application in time-critical processes •Powerful communication capabilities; the integrated PROFIBUS-DP interface in particular enables the S7- 200 to maximize its performance in distributed automation solutions. Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 3 SIMATIC S7-200 General ■ Design The SIMATIC S7-200 family consists of the following modules: •4 different basic units in different variants •14 digital and analog expansion modules •2 communications modules for connecting to PROFIBUS and AS-Interface Mechanical features •Rugged, compact plastic housing •Easily accessible wiring and operator control elements protected by front covers Design features •International standards; the SIMATIC S7-200 meets the requirements through compliance with VDE, UL, CSA and FM (Class I, Division 2, hazardous area groups A, B, C and D, T4A) standards. The quality management system used during manufacturing has ISO 9001 certification. ■ Communication The SIMATIC S7-200 offers various communication capabilities: •Point-to-point interface; can be operated in PPI, MPI (slave) mode and in user- programmable interface mode •AS-Interface connection; as master via the CP 243-2 communication processor •Connection to PROFIBUS- DP as slave; via the PROFIBUS-DP module EM 277 PPI network PPI is the communications system integrated in every S7- 200 CPU. Connections for pro- gramming or for human machi- ne interface functionality can be established over a shared twisted-pair cable. The CPUs can communicate with several other CPUs, TDs or OPs simultaneously The data transfer rate is 9.6/ 19.2/187.5 kbit/s. The following can be connected: •PG 720PII, PG 740PIII, PC RI45 PIII Tower programming devices •PCs (AT-compatible), via PC/ PPI cable •TD 200 text display; SIMATIC OP operator panels •SIMATIC S7-200; up to 31 S7-200s can be operated on a shared data bus with a programming device, PC, TD 200 or OP. Direct data ex- change between S7-200 controllers (in each case as a master) with the NETR and NETW commands. MPI network All CPUs can be connected to an MPI network (19.2/187.5 kbit/s) via the integrated interface and can then communicate with SIMATIC S7-300 ® s/S7-400 ® s. The S7- 200 CPUs are slaves in the MPI-network and cannot communicate with each other. Fig. 1 Communication in PPI mode Fig. 2 Communication in PPI mode Programming device/PC PC via PC/PPI cable or MPI card S7-200 S7-200 S7-200 SIMATIC OP TD 200 PPI network SIMATIC OP S7-400 S7-300 S7-200 MPI network Progr. device/PC PC via MPI card 4 SIMATIC S7-200 General Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 ■ Communication (cont.) Point-to-point interface, user-programmable interface mode Connection to the RS 232 interface via PC/PPI cable. Data transmission is performed with the CPU in FreePort mode; in the case of the CPU 226, both ports can be operated in FreePort mode. Data exchange takes place using a user-specific, bit-oriented communications protocol (e.g. ASCII protocol or Modbus). Maximum data transmission rate 38.4 kbit/s (adjustable). Point-to-point connections are possible to the following units: • Any data terminal equipment which has a serial interface, e.g. printers, bar-code readers •S7-200 micro PLC; e.g. for simple data exchange between two CPUs AS-Interface The SIMATIC S7-200 is connected to the AS-Interface as a master via the CP 243-2. This increases the number of inputs and outputs appre- ciably: •Up to 31 AS-Interface slaves with up to 248 binary elements PROFIBUS-DP slave PROFIBUS-DP guarantees integrated and uniform communication between all SIMATIC system components while at the same time maintaining an open system. PROFIBUS-DP’s high data transfer rate (up to 12 Mbit/s) over the integrated interface allows the real time features of the S7-200 to be used to their full extend within a distributed system structure. Response times in the millise- cond range enable applica- tions such as the following: •Motor synchronization •Interrupt-oriented applica- tions •Coordination of high-speed counting processes Fig. 3 Communication in user-programmable interface mode Fig. 4 Communication via AS-Interface Fig. 5 Communication via PROFIBUS-DP S7-200 SONAR BERO with int. AS-Interface Inductive BERO with int. AS-Interface Operator panel SIMATIC S7-300 0 1 ET 200 S7-200 SIMATIC S7-400 SIMATIC OP SIMATIC C7 Programming device SIMATIC S5 Printer Barcode reader S7-200 S7-200 Modem Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 5 SIMATIC S7-200 CPUs CPU 221, CPU 222, CPU 224, CPU 226 ■ Overview CPU 221 •The smart compact solution •W ith 10 inputs/outputs on board •Not expandable ■ CPU 222 •The top compact solution •W ith 14 inputs/outputs on board •Expandable with max. 2 expansion boards ■ CPU 224 •The compact high-perfor- mance CPU •W ith 24 inputs/outputs on board •Expandable with max. 7 expansion boards ■ CPU 226 •The powerful package for large technical tasks •W ith an additional communi- cation interface for even more flexibility and commu- nication options •W ith 40 inputs/outputs on board •Expandable with max. 7 expansion modules Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 6 SIMATIC S7-200 CPU 221, CPU 222, CPU 224, CPU 226 CPUs ■ Application CPU 221 The smart compact solution, with 10 inputs/outputs on board, cannot be extended. CPU 222 The superior compact solution with 14 inputs/outputs on board, expandable with max. 2 expansion boards. CPU 224 The compact high-perfor- mance CPU, with 24 inputs/ outputs on board, expandable with max. 7 expansion boards. CPU 226 The power pack for complex technical tasks. W ith additional communication interface for added flexibility and communication options. W ith 40 inputs/outputs on board, expandable with max. 7 expansion boards. ■ Design The CPUs include: •Integrated 24 V sensor/load power supply; for the direct connection of sensors and encoders. W ith 180 mA (CPU 221/222), 280 mA (CPU 224), 400 mA (CPU 226) it can also be used as a load power supply •2 device variants; with different supply and control voltages •Integrated digital inputs/ outputs; CPU 221: 6 inputs and 4 outputs; CPU 222: 8 inputs and 6 outputs; CPU 224: 14 inputs and 10 outputs; CPU 226: 24 inputs and 16 outputs •CPU 221/222/224: 1 communication interface; CPU 226: 2 communication interfaces; optionally - as PPI interface with PPI protocol for programming functions, HMI ® functions (TD 200, OP), S7-200- internal CPU/CPU communication (9.6/19.2/ 187.5 kbit/s) or as MPI slave for data exchange with MPI masters (S7-300/- 400, OPs, TDs, Push Button Panels) - user-programmable interface (FreePort) with interrupt capability for serial data exchange with non-Siemens devices, e.g. at the ASCII protocol baud rates 0.3/0.6/1.2/2.4/4.8/ 9.6/19.2/38.4 kbit/s; PC/PPI cable can be used as RS 232/RS 485 adapter •CPU 222/224/226: Expansion bus; connection of expansion modules (only EMs of the 22x series can be used) •Interrupt inputs; for extremely fast responses to rising or falling edges of process signals •High-speed counters; CPU 221/222: 4 high-speed counters (30 kHz); CPU 224/226: 6 high-speed counters (30 kHz), with parameteriza- ble enable and reset inputs that can be used simultaneously as up and down counters with two separate inputs and for connecting incremental encoders wtih two pulse sequences (20 kHz) with a 90° offset •CPU 222/224/226: Trouble-free expandability through digital and analog expansion modules (EM’s) •Simulator (optional); for the simulation of integrated inputs and the testing of user programs •Analog potentiometers; CPU 221/222: 1 analog potentiometers; CPU 224/226: 2 analog potentiometers, can be used as a user- friendly setpoint adjuster during everyday operation, such as for setting timers •Pulse outputs; 2 high-frequency pulse outputs (max. 20 kHz); For use in positioning tasks and the control of frequency- regulated motors and stepper motors via power circuits •Real-time clock (for insertion as optional module CPU 221/222); for example for adding time stamps to messages, for registering machine running times or for the time-control of processes •EEPROM cartridge (can optionally be inserted); allows rapid program change (even without a programming device) and additional program archiving • Battery module for long-term buffering; for extending the buffering time to typically 200 days. W ithout the battery module, user data (e.g. memory bit statuses, data blocks, timers, counters) are saved by an internal high-power capacitor for around 5 days. The program is always saved in non-volatile memory (maintenance-free). The battery module is inserted into the memory submodule slot. Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 7 SIMATIC S7-200 CPUs CPU 221, CPU 222, CPU 224, CPU 226 ■ Design (cont.) Device versions ■ Functions •Extensive set of instructions; A multiplicity of - basic operations such as binary logic operations, result allocation, save, count, create times, load, transfer, compare, shift, rotate, create complement, call sub-program (with local variables) - integrated communication commands (eg. S7-200 communication (Network read NETR, Network write NETW ) or Freeport (Transmit XMT, Receive RCV)) and - enhanced functions such as pulse-duration modulation, pulse sequence function, arith- metic functions, floating point arithmetic, PID closed-loop control, jump functions, loop functions and code conversions simplify the programming task •Counting; user-friendly counting functions in conjunction with the integrated counters und special commands for the High Speed Counter open up new application areas for the user •Interrupt handling; - Edge-triggered interrupts (triggered by either rising or falling edges of process signals at interrupt inputs) permit extremely fast reactions to process inter- rupts - Time-controlled interrupts can be set in at 1 ms incre- ments from 5 ms to 255 ms - Counter interrupts can be triggered when a specified value is reached or if the counter direction changes - Communication interrupts allow the rapid and easy exchange of information with peripheral devices such as printers or bar code readers •Direct interrogation and control of inputs/outputs; Inputs and outputs can also be interrogated and set independently of the cycle. The controller can so react quickly to process events (e.g. direct resetting of outputs when interrupt occurs) •Password protection; the 3-level password protection concept safeguards effec- tively your know-how. The protection concept has the following options for access to the user program: - Full access: The program can be altered as desired. - Read only: The program is protected against unautho- rized alteration. Testing, adjustment of system parameters and copying of the program is allowed. - Complete protection: The program is protected against alteration and un- authorized readout and copying. Adjustment of pa- rameters is allowed. •Test and diagnostic functions; User-friendly functions support testing and diagnostics: the complete program is run over a prede- termined number of cycles and analyzed. Internal parameters such as memory bits, timers or counters are logged at the same time over a maximum of 124 cycles. •”Forcing” of inputs and outputs during test and diagnostic operation; Inputs and outputs can be set independently of cycle and thus permanently, for example to test the user program. •Runtime edit: •During RUN mode, programs can be edited and modified programs can be loaded into the CPU with a mouse click without having to interrupt the running program •Additional mathematical functions, e.g. SIN, COS, TAN, LN, EXP CPU 224, CPU 226 in addi- tion: •Runtime edit: During RUN mode, pro- grams can be edited and modified programs can be loaded into the CPU with a mouse click without having to interrupt the running pro- gram •Additional mathematical functions, e.g. SIN, COS, TAN, LN, EXP ■ Programming The STEP ® 7-Micro/W IN32 V3 programming package permits complete programming of all S7-200- CPUs Note The CPU 22x cannot be programmed using STEP 7- Micro/DOS. For programming via the seri- al interface of the program- ming device/PC, a PC/PPI cable is required. W hen using the STEP 7-Micro/ W in32 V3 programming soft- ware, programming is also possible via the SIMATIC CPs CP 5511 or CP 5611 (see Catalog IK PI) or the MPI interface of the programming device. This increases the maximum permissible transmission rate to 187.5 kbit/s. Version Supply voltage Input voltage Output voltage Output current CPU 221/222/224/226 DC outputs 24 V DC 24 V DC 24 V DC 0.75 A, transistor Relay outputs 85 to 264 V AC 24 V DC 24 V DC , 24 to 230 V AC 2 A, relay 8 Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 SIMATIC S7-200 CPU 221, CPU 222, CPU 224, CPU 226 CPUs ■ Technical specifications CPU 221 Program memory 4 kbytes Data memory 2 kbytes Memory cartridge (optional) 1 pluggable memory cartridge; content identical to the inte- grated EEPROM Program backup entire program maintenance-free in the integrated EEPROM Data backup • entire DB 1 loaded from pro- gramming device/PC into inte- gral EEPROM; maintenance-free • current DB 1 values in RAM, re- tentive memory bits, timers, counters etc. maintenance-free through super capacitor; optional battery for long-term backup. Backup time typ. 50 h (min. 8 h at 40 °C); 200 days (typ.) with optional bat- tery module Programming language LAD, FBD and STL Program organization 1 OB, 1 DB, 1 SDB Subroutines with/without parame- ter passing Program execution • free cycle (OB 1) • interrupt-controlled • time controlled (1 to 255 ms) Subroutine levels 8 User program protection 3-stage password protection Operation set Bit logic operations, comparison operations, timer operations, counting operations, clock opera- tions, fixed-point arithmetic, float- ing-point arithmetic, numerical functions, move operations, table operations, logic operations, shift and rotate operations, conver- sion operations, program control operations, interrupt and commu- nication operations, stack opera- tions Execution times for bit operations 0.37 µs Cycle time monitoring 300 ms (retriggerable) Bit memories 256 • of these retentive 0 to 112 in EEPROM, selectable; 0 to 256, via super capacitor or battery, selectable Counter 256 • of these retentive 256, via super capacitor or battery, selectable • Counting range 0 to 32767 Timers 256 • of these retentive 64, via super capacitor or battery, selectable • range 4 timers, 1 ms to 30 s 16 timers, 10 ms to 5 min 236 timers, 100 ms to 54 min Integrated high speed functions • Interrupt inputs 4 (4 rising edges and/or 4 falling edges) • Counters 4 fast counters (each with 30 kHz), 32 bits (incl. sign), can be used as up/down counters or for connecting 2 incremental encoders with pulse trains offset by 90°; (max. 20 kHz (A/B counter)); with parameterizable enable and reset inputs; Interrupt options (inc. calling a subroutine with any content) on reaching a specified value; reversal of counting direction etc. • Pulse outputs 2 high-speed outputs, 20 kHz, with interrupt option; pulse width and frequency modulation possi- ble Interfaces 1 RS 485 communication interface, optionally: • as PPI interface with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200-internal CPU/CPU communication; Baud rates 9.6/19.2/187.5 kbit/s • or as MPI slave for data exchange with MPI masters (S7- 300/S7-400 CPU’s, OP’s, TDs, push-button panels); S7-200- internal CPU/CPU communication is not possible in the MPI network; transmission rates 19.2/187.5 kbit/s • or as user-programmable interface with interrupt capability for serial data exchange with non-Siemens devices, e.g. at ASCII protocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/ 38.4 kbit/s; at 1.2 to 38.4 kbit/s the PC/PPI cable can be used as an RS232/ RS458 adapter Connectable programming units/PC PG 720 PII, PG 740 PIII, PC RI 45 PIII Tower, standard PCs Integrated inputs/outputs • Plug-in I/O terminals No • Digital inputs 6 • Digital outputs 4 • Analog potentiometer 1 analog potentiometer; 8 bit resolution Max. number of inputs/outputs • Digital inputs/outputs max. 6 inputs and 4 outputs (inte- grated inputs/outputs); no extension possible • Analog inputs/outputs - • AS-Interface inputs/outputs, max. - Expansion, max. - Degree of protection IP 20 in accordance with IEC 529 Ambient temperature • with horizontal installation 0 to 55 °C • when mounted vertically 0 to 45 °C Relative humidity 5 to 95% (RH severity level 2 in accordance with IEC 1131-2) Atmospheric pressure 860 to 1080 hPa Other environmental conditions see “S7-200 Programmable Controller, system manual” 9 Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 SIMATIC S7-200 CPUs CPU 221, CPU 222, CPU 224, CPU 226 ■ Technical specifications CPU 221 (cont.) Power supply: 24 V DC 100 to 230 V AC Inputs: 24 V DC 24 V DC Outputs: 24 V DC Relay Supply voltage L+/L1 • rated value 24 V DC 100 to 230 V AC • permitted range 20.4 to 28.8 V 85 to 264 V AC (47 to 63 Hz) Input current • max. incl. load 10 A at 28.8 V 20 A at 264 V • power consumption max. 80 to 900 mA 15 to 60 mA (240 V) 30 to 120 mA (12 V) Output voltage for sensors and transmitters • rated value L+ (24 V DC) 24 V DC • permitted range 15.4 to 28.8 V 20.4 to 28.8 V Output current for sensors (24 V DC) • rated value 180 mA 180 mA • short-circuit protection electronic at 600 mA electronic at 600 mA Output current for expansion modules (5 V DC) Integrated inputs 6 6 • Type optionally active high and active low per group optionally active high and active low per group Input voltage • rated value 24 V DC 24 V DC • for "1" signal, min. 15 V 15 V • for "0" signal 0 to 5 V 0 to 5 V Galvanic isolation Optocoupler Optocoupler • in groups of 2 and 4 2 and 4 Input current • rated value for "1" signal 4 mA 4 mA Input delay (at rated value of the input voltage) • for standard inputs max. every 0.2 to 12.8 ms, selectable every 0.2 to 12.8 ms, selectable • for interrupt inputs (I0.0 to I0.3) 0.2 to 12.8 ms, selectable (I0.0 to I0.3) 0.2 to 12.8 ms, selectable • for fast counters max. (I0.0 to I0.5) 30 kHz (I0.0 to I0.5) 30 kHz Connection of 2-wire BERO • Permissible quiescent cur- rent, max. 1 mA 1 mA Cable lengths • unshielded (not for high- speed signals) 300 m 300 m • shielded - standard input - high-speed counters 500 m 50 m 500 m 50 m Power supply: 24 V DC 100 to 230 V AC Inputs: 24 V DC 24 V DC Outputs: 24 V DC Relay Integrated outputs 4 (transistor) switchable in parallel for higher output currents 4 (relay) Rated load voltage L+/L1 24 V DC 24 V DC/ 24 to 230 V AC • permitted range 20.4 to 28.8 V DC 5 to 30 V DC/ 5 to 250 V AC Output voltage • for "1" signal, min. 20 V DC L+/L1 Galvanic isolation Optocoupler Relay • in groups of 4 1 and 3 Output current max. • for "1" signal - rated value at 40 °C 0.75 A 2 A - rated value at 55 °C 0.75 A 2 A • min. current - - • for "0" signal 0.1 mA 0 mA Sum of all output currents • at 40 °C, max. 3.0 A 6.0 A • at 55 °C, max. (horizontal in- stallation) 3.0 A 6.0 A ON delay • of the standard outputs, max. (O0.2 to O0.3) 15 µs (all outputs) 10 ms • of the pulse outputs, max. (O0.0 to O0.1) 2 µs - OFF delay • of the standard outputs, max. (O0.2 to O0.3) 100 µs (all outputs) 10 ms • of the pulse outputs, max. (O0.0 to O0.1) 10 µs - Operating frequency of the pulse outputs (O0.0 to O0.1) (O0.0 to O0.1) • for resistive load 20 kHz - Switching capacity of the out- puts • for resistive load 0.75 A 2 A • for a lamp load 5 W 30 W DC 200 W AC Service life of the contacts (number of switching cycles to VDE 0660, Part 200) • mechanical - 10 mill. • at rated load - 100.000 Limitation of voltage induced on circuit interruption, max. 1 W - Short-circuit protection provide externally provide externally Cable lengths • unshielded 150 m 150 m • shielded 500 m 500 m Isolation • between 24 V DC and 5 V DC 500 V DC 500 V DC • betw. 24 V DC and 230 V AC - 1500 V AC Dimensions (W x H x D) in mm 90 x 80 x 62 90 x 80 x 62 W eight, approx. 270 g 310 g 10 Micro PLC SIMATIC S7-200 September 2000 Extract from Siemens Catalog ST 70 SIMATIC S7-200 CPU 221, CPU 222, CPU 224, CPU 226 CPUs ■ Technical specifications CPU 222 Program memory 4 kbytes Data memory 2 kbytes Memory cartridge (optional) 1 pluggable memory cartridge; content identical to the inte- grated EEPROM Program backup Entire program maintenance-free in the integrated EEPROM Data backup • Entire DB 1 loaded from pro- gramming device/PC into inte- gral EEPROM; maintenance-free • Current DB 1 values in RAM, re- tentive flags, timers, counters etc. maintenance-free through super capacitor; optional battery for long-term backup Backup time typ. 50 h (min. 8 h at 40 °C); 200 days (typ.) with optional bat- tery module Programming language LAD, FBD and STL Program organization 1 OB, 1 DB, 1 SDB Subroutines with/without parame- ter passing Program execution • free cycle (OB 1) • interrupt-controlled • time controlled (1 to 255 ms) Subroutine levels 8 User program protection 3-level password protection Operation set Bit logic operations, comparison operations, timer operations, counting operations, clock opera- tions, fixed-point arithmetic, float- ing-point arithmetic, numerical functions, move operations, table operations, logic operations, shift and rotate operations, conver- sion operations, program control operations, interrupt and commu- nication operations, stack opera- tions Execution times for bit operations 0.37 µs Cycle time monitoring 300 ms (retriggerable) Bit memories 256 • of these retentive 0 to 112 in EEPROM, selectable; 0 to 256, via super capacitor or battery, selectable Counter 256 • of these retentive 256, via super capacitor or battery, selectable • counting range 0 to 32767 Timers 256 • of these retentive 64, via super capacitor or battery, selectable • range 4 timers, 1 ms to 30 s 16 timers, 10 ms to 5 min 236 timers, 100 ms to 54 min Integrated high-speed functions • Interrupt inputs 4 (4 rising edges and/or 4 falling edges) • Counters 4 fast counters (each with 30 kHz), 32 bits (incl. sign), can be used as up/down counters or for connecting 2 incremental encoders with pulse trains offset by 90°; (max. 20 kHz (A/B-Counter)); with parameterizable enable and reset inputs; Interrupt options (inc. calling a subroutine with any content) on reaching a specified value; Reversal of counting direction etc. • Pulse outputs 2 high-speed outputs, 20 kHz, with interrupt option; pulse width and frequency modulation possi- ble Interfaces 1 RS 485 communication interface, optionally: • as PPI interface with PPI protocol for programming functions, HMI functions (TD 200, OP), S7-200-internal CPU/ CPU communication; Baud rates 9.6/19.2/187.5 kbit/s • or as MPI slave for data exchange with MPI masters (S7- 300/S7-400 CPU’s, OP’s, TDs, push-button panels); S7-200- internal CPU/CPU communication is not possible in the MPI network; transmission rates 19.2/187.5 kbit/s • or as user-programmable interface with interrupt capability for serial data exchange with non-Siemens devices, e.g. at ASCII protocol baud rates: 0.3/0.6/1.2/2.4/4.8/9.6/19.2/ 38.4 kbit/s; at 1.2 to 38.4 kbit/s the PC/PPI cable can be used as an RS232/ RS485 adapter Expansion bus: • Connection of expansion mod- ules (EM) 1) Connectable programming units/PC PG 720 PII, PG 740 PIII, PC RI45 PIII Tower, standard PC Integrated inputs/outputs • Plug-in I/O terminals No • Digital inputs 8 • Digital outputs 6 • Analog potentiometer 1 analog potentiometer; 8 bit resolution Max. number of inputs/outputs • Digital inputs/outputs max. 40 inputs and 38 outputs (CPU + EM) • Analog inputs/outputs max. 8 inputs and 2 outputs (EM) or max. 0 inputs and 4 outputs (EM) • AS interface inputs/outputs, max. max. 31 AS-Interface slaves (CP 243-2) Expansion, max. 2 expansion modules 1) Degree of protection IP 20 in accordance with IEC 529 Ambient temperature • with horizontal installation 0 to 55 °C • when mounted vertically 0 to 45 °C 1) Only S7-22x series expansion modules can be used. Because of the limited output current, the use of expansion boards can be subject to restrictions. [...]... for PROFIBUS 6ES7 972-0AA01-0XA0 see page 45 see page 45 with 12 interfaces (for CPU 22x) 6ES7 292-1AE20-0AA0 CP 5511 with 14 interfaces (for CPU 22x) 6ES7 292-1AF20-0AA0 CP 5611 with 18 interfaces (for CPU 22x) 6ES7 292-1AG20-0AA0 18 Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 SIMATIC S7- 200 Digital expansion modules EM 221, EM 222, EM 223 SIMATIC S7- 200 s Overview s... modules for the S7- 21x and the S7- 22x series CPUs of the S7- 21x series can only be expanded using expansion modules of the S7- 21x series CPUs of the S7- 22x series (CPU 222/224/ 226) can only be expanded using expansion modules of the S7- 22x series Combined use of the various series is not possible Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 19 SIMATIC S7- 200 Digital expansion... • 16 inputs, 24 V DC, 16 outputs, relay 6ES7 291-3AX20-0XA0 6ES7 223-1BF20-0XA0 Pluggable terminal block (spare part) 6ES7 223-1BH21-0XA0 • with 7 interfaces (for EM 221/222) 6ES7 292-1AD20-0AA0 6ES7 223-1BL21-0XA0 • with 12 interfaces (for EM 223) 6ES7 292-1AE20-0AA0 Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 23 SIMATIC S7- 200 Analog expansion modules EM 231, EM 232,... Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 17 SIMATIC S7- 200 CPUs CPU 221, CPU 222, CPU 224, CPU 226 s Ordering data CPU 221 PC-to-PPI cable 24 V DC supply, 24 V DC inputs, 24 V DC outputs 6ES7 211-0AA21-0XB0 100-230 V AC supply, 24 V DC inputs, relay outputs 6ES7 211-0BA21-0XB0 CPU 222 6ES7 901-3BF20-0XA0 5 m; with integral RS 232C/RS 485 adapter, between S7- 200 and... 7-Micro/WIN32 V3.1 programming software Grounding terminal 10 ea S7- 200 programmable controller, system manual 6ES7 298-8FA21-8AH0 6ES7 298-8FA21-8BH0 6ES7 298-8FA21-8CH0 6ES7 298-8FA21-8DH0 6ES7 298-8FA21-8EH0 see page 40 PROFIBUS IP 20 bus connector with 90° cable outlet • without PG interface 6ES7 972-0BA11-0XA0 • with PG interface 6ES7 291-3AX20-0XA0 6ES7 972-0BB11-0XA0 PROFIBUS IP 20 bus connector with 35°... Application The TD 200 text display is the optimum solution to all SIMATIC S7- 200 human machine interface functions It is simply connected with the enclosed connecting cable to the PPI interface of the S7- 200 A separate power supply is not required Several TD 200 can be connected to one S7- 200 The TD 200 can be used for the following tasks: • Message text display • Accessing the PLC program - for example,... of resistance temperature detectors 6ES7 231-7PB20-0XA0 Grounding terminal 10 ea 6ES5 728-8MA11 Front flap set contains various covering flaps for CPU and EM; spare part 6ES7 291-3AX20-0XA0 Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 31 SIMATIC S7- 200 Communication modules EM 277 PROFIBUS-DP module s Overview • For connection of S7- 22x to PROFIBUS-DP (as slave) and MPI... +/-5% s Ordering data SITOP power 24 V/3.5 A load power supply 6EP1 332-1SH31 120/230 V AC; 24 V DC/3.5 A Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 35 SIMATIC S7- 200 Human Machine Interface TD 200 text display s Overview • The user-friendly text display for the S7- 200 • No separate power supply required • For human machine interface functionality: • No separate parameterization... pressure 860 to 1080 hPa Other environmental conditions see S7- 200 Programmable Controller, system manual” 1) Only S7- 22x series expansion modules can be used Because of the limited output current, the use of expansion boards can be subject to restrictions 14 Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 SIMATIC S7- 200 CPUs CPU 221, CPU 222, CPU 224, CPU 226 s Technical specifications... connection of thermocouples and for the measurement of analog signals at low levels 6ES7 231-7PD20-0XA0 Grounding terminal 10 ea 6ES5 728-8MA11 Front flap set contains various covering flaps for CPU and EM; spare part 6ES7 291-3AX20-0XA0 Micro PLC SIMATIC S7- 200 September 2000 Extract from Siemens Catalog ST 70 29 SIMATIC S7- 200 Analog expansion modules EM 231 RTD module s Overview • For convenient measuring . card S 7-2 00 S 7-2 00 S 7-2 00 SIMATIC OP TD 200 PPI network SIMATIC OP S 7-4 00 S 7-3 00 S 7-2 00 MPI network Progr. device/PC PC via MPI card 4 SIMATIC S 7-2 00 General. 29 2-1 AE2 0-0 AA0 with 14 interfaces (for CPU 22x) 6ES7 29 2-1 AF2 0-0 AA0 with 18 interfaces (for CPU 22x) 6ES7 29 2-1 AG2 0-0 AA0 PC-to-PPI cable 6ES7 90 1-3 BF2 0-0 XA0

Ngày đăng: 08/01/2014, 01:44

Tài liệu cùng người dùng

Tài liệu liên quan