Tài liệu Diagnostics Guide 10/2002 Edition pdf

219 291 0
Tài liệu Diagnostics Guide 10/2002 Edition pdf

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

Diagnostics Guide 10/2002 Edition Diagnostics Guide 10/2002 Edition sinumerik SINUMERIK 802D SINUMERIK 802D base line SINUMERIK 802D Diagnostics Guide Valid for Control Software version SINUMERIK 802D as of 1 10.02 Edition Alarms 1 Glossary / Abbreviations 2 SINUMERIK  documentation Printing history Brief details of this edition and previous editions are listed below. The status of each edition is shown by the code in the ”Remarks” column. Status code in the ”Remarks” column: A New documentation . . . B Unrevized reprint with new Order No . . . C Revised edition with new status. . . . . If actual changes have been made on the page since the last edition, this is indicated by a new edition coding in the header on that page. Edition Order No. Remarks 11.00 6FC5698-2AA20-0BP0 A 10.02 6FC5698-2AA20-0BP1 C This Manual is included on the documentation on CD-ROM (DOCONCD) Edition Order No. Remarks 11.02 6FC5298-6CA00-0BG3 C Trademarks SIMATICr, SIMATIC HMIr, SIMATIC NETr, SIROTECr, SINUMERIKr and SIMODRIVEr are registered trademarks of Siemens. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of trademark owners. Siemens-AktiengesellschaftOrder No. 6FC5698-2AA20-0BP1 Printed in the Federal Republic of Germany This documentation was produced using Interleaf 7.0. Subject to change without prior notice. The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for demages. All rights, including rights created by patent grant or registration of utility model or design, are reserved.  Siemens AG 2002. All rights reserved. Other functions not described in this documentation might be executable in the control. This does not, however, represent an obligation to supply such functions with a new control or when servicing. We have checked that the contents of this document correspond to the hardware and software described. Nonetheless, differences might exist and therefore we cannot guarantee that they are completely identical. The information contained in this document is, however, reviewed regularly and any necessary changes will be included in the next edition. We welcome suggestions for improvement. 10.02 © Siemens AG 2002 All Rights Reserved 6FC5698-2AA20-0BP1 802D (DG) v Preface The present description is intended to be used as a reference manual. It allows the operator on the machine tool to: - access special cases in the operation of the machine correctly; - to learn the response of the system/installation to the particular spe- cial case; - to use the possibilities of continuing work after the special case; - to follow notes for further references. Object of the present description are the alarms occurring in the areas NC kernel (NCK), Profibus, cycles and PLC. Further alarms may occur in the HMI area (Human Machine Interface). They are announced to the user by self-explaining alarm lines displayed on the operator panel. These alarms are not part of this Diagnostics Guide. For special cases in conjunction with the integrated PLC, please refer to the relevant SIMATIC S7-200 system documentation. The alarms are sorted in the Diagnostics Guide by ascending alarm numbers with gaps between them. Danger Please always check the situation of the particular system/installation carefully on the basis of the alarms occurred. Eliminate the causes for the occurrence of the alarms and acknowledge them as described. Otherwise, danger will result for machine, workpiece, saved settings and - under certain circumstances - even for your health. Table 1_1 Alarm number ranges 000 000 - 009 999 General alarms 010 000 - 019 999 Channel alarms 020 000 - 029 999 Axis / spindle alarms 030 000 - 099 999 Functional alarms 060 000 - 064 999 SIEMENS cycle alarms 065 000 - 069 999 User cycle alarms Scope Sorting Safety NC alarms 10.02 6FC5698-2AA20-0BP1 © Siemens AG 2002 All Rights Reserved vi 802D (DG) Table 1_2 Alarm number ranges (cont'd.) 100 000 - 100 999 Basic system HMI0 101 000 - 101 999 Diagnosis 102 000 - 102 999 Services 103 000 - 103 999 Machine 104 000 - 104 999 Parameters 105 000 - 105 999 Programming 106 000 - 106 999 Reserve 107 000 - 107 999 OEM 110 000 - 110 999 Reserved 120 000 - 120 999 Reserved Table 1_4 Alarm number ranges (cont'd.) 400 000 - 499 999 General alarms 700 000 - 799 999 User area HMI alarms/messages PLC alarms/messages 10.02 © Siemens AG 2002 All Rights Reserved 6FC5698-2AA20-0BP1 802D (DG) vii Contents Alarms 9 1.1 Overview of NC alarms 10 1.2 Profibus Alarms 180 13 Cycle Alarms| . 187 1.4 ISO Alarms . 197 15 PLC Alarms 199 1.6 Action List 202 Glossary / Abbreviations 209 2.1 Abbreviations . 209 2.2 Glossary . 213 10.02 6FC5698-2AA20-0BP1 © Siemens AG 2002 All Rights Reserved viii 802D (DG) 10.02 1 Alarms © Siemens AG 2002 All Rights Reserved 6FC5698-2AA20-0BP1 802D (DG) 1-9 Alarms Alarms with alarm number 1xxx are system errors that indicate internal error states. The internal error number transmitted provides the devel- oper important information with regard to the error cause and the error location. These system errors are not described in detail. If they occur with the supplied control systems at all, please contact the following hotline, specifying the alarm number, the alarm text and the internal system error number contained therein: Hotline Germany Siemens AG, A&D MC Tel. +49 (0) 180 525 80 08 Fax +49 (0) 180 525 80 09 Hotline China Siemens Numerical Control Ltd. Development & Engineering Division Tel. (025) 2 18 18 88 (Ext. 305) Fax (025) 2 18 16 66 1 [...]... backup copy are lost The cause of this procedure is to be searched for in exceeding of the buffer time Please make sure that the required on-time of the control system, which is specified in your Start-up Guide, is not exceeded The current backup copy of the battery-backed memory was created using the internal data backup carried out last using the softkey "Save data" in the HMI Reaction Alarm display Interface . Diagnostics Guide 10/2002 Edition Diagnostics Guide 10/2002 Edition sinumerik SINUMERIK 802D SINUMERIK 802D base line SINUMERIK 802D Diagnostics Guide. of 1 10.02 Edition Alarms 1 Glossary / Abbreviations 2 SINUMERIK  documentation Printing history Brief details of this edition and previous editions are

Ngày đăng: 22/12/2013, 22:15

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan