code of practice for energy efficiency of lighting installations

48 321 0
code of practice for energy efficiency of lighting installations

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

[...]... SUBMISSION OF INFORMATION 5.1 The following standard forms are relevant to the provision of information in relation to this Code :FORM LG-1 : Data of Lamps & Luminaires FORM LG-2 : Lighting Power Density FORM LG-3 : List of Submitted Drawings and Documents Page 10 of 38 Code of Practice for Energy Efficiency of Lighting Installations Schedule of Forms FORM LG -(G) : Summary of Information on Lighting Installations. .. Lighting Installations FORM LG -1 : Data of Lamps & Luminaires FORM LG -2 : Lighting Power Density FORM LG -3 : List of Submitted Drawings and Documents Code of Practice for Energy Efficiency of Lighting Installations Note: this page is blank FORM LG – (G) Ref No [ for office use only ] Summary of Information on Lighting Installations Part (A) : General Information on Lighting Installation... Page 7 of 38 35 25 25 Code of Practice for Energy Efficiency of Lighting Installations Table (LG4) : Maximum Allowable Values of Lighting Power Density for Various Types of Space (Continued) Space Code Type of Space F Indoor Sports Grounds F.1 F.2 Maximum Allowable Lighting Power Density (W/m2) Spectator Seating Area Indoor Sports Ground for Badminton, Basketball, Volleyball or Table Tennis : • for amateur... for a multi-functional space are as follows : a) The lighting power density of each combination of luminaires should not exceed the maximum allowable value corresponding to the type of space illuminated by that combination of luminaires b) Each combination of luminaires should be provided with an independent lighting control facility Page 8 of 38 Code of Practice for Energy Efficiency of Lighting Installations. .. Area of an Office ≤ 200 m 2 Minimum No of Lighting Control Points Office Area ≤ 10 m2 1 10 m2 < Office Area ≤ 20 m2 2 20 m2 < Office Area ≤ 30 m2 3 10 × (N-1) m2 < Office Area ≤ 10 × N m2 N ( N is an integer) Page 9 of 38 Table (LG6) : Minimum Number of Lighting Control Points for Office Space > 200 m2 Space Area of an Office > 200 m2 Minimum No of Lighting Control Points 50 x (N-20) + 200 m2 < Office... Part (B) : Submitted LG Forms LG Forms No of Sheets Submitted Form LG-(G) : Summary of Information on Lighting Installations Form LG – 1 : Data of Lamps & Luminaires Form LG – 2 : Lighting Power Density Form LG – 3 : List of Submitted Drawings & Documents Remark : * delete as appropriate ** select appropriate building type(s) # Total Installed Lighting Power refers to the sum of circuit wattage (i.e... (quoted from Form LG-1) (lux) {N} Page 13 of 38 (W) Lighting Power Density Calculated LPD This Column is reserved for Office Use {N} x {CW} {A} Maximum Allowable LPD (W/m2) (W/m2) ) Form LG – 3 Ref No [for office use only] LIST OF SUBMITTED DRAWINGS & DOCUMENTS Name of Building : Identification Number of Version Drawing / document No Sheet ( ) of ( Title of Drawing / Document Page 14 of 38 No of Copies... occupants of a space, the lighting control points should be located at positions that are easily accessible to the occupants 4.4.2 For any space that is classified as an open plan office, a cellular office or a drawing office, the minimum number of lighting control points for that office space is given in Table (LG5) and Table (LG6) Table (LG5) : Minimum Number of Lighting Control Points for Office Space... considered less energy- efficient comparing with other lamp types Page 5 of 38 Code of Practice for Energy Efficiency of Lighting Installations 4.2 Maximum Allowable Lamp Controlgear Loss For any lamp of a type as listed in Table (LG3), the lamp controlgear loss should be equal to or smaller than the corresponding maximum allowable value as listed in Table (LG3) Table (LG3) : Maximum Allowable Values of Lamp.. .Code of Practice for Energy Efficiency of Lighting Installations Table (LG2): Minimum Allowable Values of Luminous Efficacy for Various Types of Lamps (Continued) Lamp Type Low Pressure Sodium Vapour Nominal Lamp Wattage Lamp Code { Lw } SOX {Lw} < 40 W Minimum Allowable Luminous Efficacy (lm/W) 130 40 W ≤ {Lw} . x0 y0 w1 h1" alt="" Code of Practice for Energy Efficiency of Lighting Installations - i - Foreword The Code of Practice for Energy Efficiency of Lighting Installations aims to. Documents Code of Practice for Energy Efficiency of Lighting Installations Schedule of Forms FORM LG -(G) : Summary of Information on Lighting Installations FORM LG. 38 Code of Practice for Energy Efficiency of Lighting Installations Note: this page is blank Code of Practice for Energy Efficiency of Lighting Installations Page 1 of 38 1. SCOPE

Ngày đăng: 28/09/2014, 23:45

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan