INTERNATIONAL ENERGY CONSERVATION CODE phần 8 doc

10 298 0
INTERNATIONAL ENERGY CONSERVATION CODE phần 8 doc

Đang tải... (xem toàn văn)

Thông tin tài liệu

COMMERCIAL ENERGY EFFICIENCY TABLE 505.5.2-continued INTERIOR LIGHTING POWER ALLOWANCES LIGHTING POWER DENSITY Building Area Type a (W/ft 2 ) Transportation 1.0 Warehouse 0.8 Workshop 1.4 For SI: 1 foot =304.8 mm, 1 watt per square foot = W/O.0929 m 2 • a. In cases where bothageneral building area type and a more specific building area type are listed, the more specific building area type shall apply. b. Where lighting equipment is specified to be installed to highlight specific merchandise in addition to lighting equipment specified for general lighting and is switched or dimmed on circuits different from the circuits for general lighting, the smaller of the actual wattage of the lightingequipmentinstalled specifically for merchandise, or additional lighting power as determined below shall be added to the interiorlightingpower determined in accordance with this line item. Calculate the additional lighting power as follows: Additional Interior Lighting Power Allowance = 1000 watts + (Retail Area 1 x 0.6W/ft 2 ) + (Retail Area 2 x 0.6W/ft 2 ) + (Retail Area 3 x 1.4W/ft 2 ) + (Retail Area 4 x 2.5W/ft 2 ). where: Retail Area 1 = The floor area for all products not listed in Retail Area 2, 3 or 4. Retail Area 2 = The floor area used for the sale of vehicles, sportinggoods and small electronics. Retail Area 3 = The floor area used for the sale of furniture, clothing, cos- metics and artwork. Retail Area 4 = The floor area used for the sale of jewelry, crystal and china. Exception: Other merchandise categories are permitted to be included in Retail Areas 2through4above, provided thatjustificationdocument- ing the need for additional lighting power based on visual inspection, contrast, or other critical display is approvedby the authority having jurisdiction. 505.6 Exterior lighting. (Mandatory). When the power for exterior lighting is supplied through the energy service to the building, all exterior lighting, otherthan low-voltage landscape lighting, shall comply with Sections 505.6.1 and 505.6.2. Exception: Where approved because of historical, safety, signage or emergency considerations. 505.6.1 Exterior building grounds lighting. All exterior building grounds luminaires that operateat greater than 100 watts shall contain lamps having a minimum efficacy of 60 lumens per watt unless the luminaire is controlled by a motion sensor or qualifies for one of the exceptions under Section 505.6.2. 505.6.2 Exterior building lighting power. The total exte- rior lighting power allowance for all exterior building appli- cations is the sum of the base site allowance plus the individual allowances for areas that are to be illuminated and are permitted in Table 505.6.2 (2) for the applicable lighting zone. Tradeoffs are allowed only among exterior lighting applications listed in Table 505.6.2(2), Tradable Surfaces section. The lighting zone for the building exterior is determined from Table 505.6.2 (1) unless otherwise speci- fied by the localjurisdiction. Exterior lighting for all appli- cations (except those included in the exceptions to Section 60 505.6.2) shall comply with the requirements of Section 505.6.1. Exceptions: Lighting used for the following exterior applications is exempt when equipped with a control device independent of the control of the nonexempt lighting: 1. Specialized signal, directional and marker lighting associated with transportation; 2. Advertising signage or directional signage; 3. Integral to equipment or instrumentation and is installed by its manufacturer; 4. Theatrical purposes, including performance, stage, film production and video production; 5. Athletic playing areas; 6. Temporary lighting; 7. Industrial production, material handling, transpor- tation sites and associated storage areas; 8. Theme elements in theme/amusement parks; and 9. Used to highlight features of public monuments and registered historic landmark structures or buildings. TABLE 505.6.2(1) EXTERIOR LIGHTING ZONES LIGHTING ZONE DESCRIPTION 1 Developed areas of national parks, state parks, forest land, and rural areas Areas predominantly consisting of residential 2 zoning, neighborhood business districts, light industrial with limited nighttime use and residential mixed use areas 3 All other areas High-activity commercial districts in major 4 metropolitan areas as designated by the local land use planning authority 505.7 Electrical energy consumption. (Mandatory). In buildings having individual dwelling units, provisions shall be made to determine the electrical energy consumed byeach ten- ant by separately metering individual dwelling units. SECTION 506 TOTAL BUILDING PERFORMANCE 506.1 Scope. This section establishes criteria for compliance using total building performance. The following systems and loads shall be included in determining the total building perfor- mance: heating systems, cooling systems, service water heat- ing' fan systems, lighting power, receptacle loads and process loads. 506.2 Mandatory requirements. Compliance with this sec- tion requires that the criteria of Sections 502.4, 503.2, 504 and 505 be met. 2009 INTERNATIONAL ENERGY CONSERVATION CODE® TABLE 505.6.2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS COMMERCIAL ENERGY EFFICIENCY APPLICATIONS LIGHTING POWER DENSITIES Tradable Surfaces (Lighting Power Densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs, and outdoor sales areas may be traded.) Uncovered Parking Areas Parking Lots and drives 0.15 W/ft 2 Building Grounds Walkways less than 10 feet wide 1.0 watts/linear foot Walkways 10 feet wide or greater, plaza areas and special feature areas 0.2 W/ft 2 Stairways 1.0 W/ft 2 Building Entrances and Exits Main entries 30 watts/linear foot of door width Other doors 20 watts/linear foot of door width Canopies and Overhangs Canopies (free standing & attached and overhangs) 1.25 W/ft 2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/ft 2 Street frontage for vehicle sales lots in addition to " open area" allowance 20 watts/linear foot Nontradable Surfaces (Lighting Power Density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the Tradable Surfaces section of this table.) Building facades 0.2 W/ft 2 for each illuminated wall or surface or 5.0 Watts/linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 watts per location plus 90 watts per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/ft 2 of uncovered area (covered areas are included in the Canopies and Overhangs section of Tradable Surfaces) Loading areas for law enforcement, fire, ambulance and other emergency 0.5 W /ft2 of uncovered area (covered areas are included in service vehicles the Canopies and Overhangs section of Tradable Surfaces) Drive-up windows at fast food restaurants 400 watts per drive-through Parking near 24-hour retail entrances 800 watts per main entry For 51: 1 foot = 304.8 mm, 1 watt per square foot =W/0.0929 m 2 • 2009 INTERNATIONAL ENERGY CONSERVATION CODE® 61 COMMERCIAL ENERGY EFFICIENCY TABLE 505.6.2(2) INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS Zone 1 Zone 2 Zone 3 Zone 4 Base Site Allowance (Base allowance may be 500W 600W 750W 1300W used in tradable or nontradable surfaces.) Uncovered Parking Areas Parking areas and drives 0.04 W/ft 2 0.06 W/ft 2 0.10 W/ft 2 0.13 W/ft 2 Building Grounds Walkways less than 0.7 W/linear foot 0.7 W/linear foot 0.8 W/linear foot 1.0 W/linear foot 10 feet wide Walkways 10 feet wide 0.14 W/ft 2 0.14 W/ft 2 0.16 W/ft 2 0.2 W/ft 2 or greater, plaza areas special feature areas Stairways 0.75 W/ft 2 1.0 W/ft 2 1.0 W/ft 2 1.0 W/ft 2 Pedestrian tunnels 0.15 W/ft 2 0.15 W/ft 2 0.2 W/ft 2 0.3 W/ft 2 Tradable Surfaces (Lighting power Building Entrances and Exits densities for uncovered parking areas, building Main entries 20 W/linear foot 20 W/linear foot 30 W/linear foot 30 W/linear foot grounds, building of door width of door width of door width of door width entrances and exits, 20 W/linear foot 20 W/linear foot 20 W/linear foot 20 W/linear foot canopies and overhangs Other doors of door width of door width of door width of door width and outdoor sales areas may be traded.) Entry canopies 0.25 W/ft 2 0.25 W/ft 2 0.4 W/ft 2 0.4 W/ft 2 Sales Canopies Free-standing and 0.6 W/ft 2 0.6 W/ft 2 0.8 W/ft 2 1.0 W/ft 2 attached Outdoor Sales Open areas (including 0.25 W/ft 2 0.25 W/ft 2 0.5 W/ft 2 0.7 W/ft 2 vehicle sales lots) Street frontage for vehicle sales lots in No allowance lOW/linear foot lOW/linear foot 30 W/linear foot addition to "open area " allowance 0.1 W/ft 2 for each 0. 15 W/ft 2 for each 0.2 W/ft 2 for each illuminated wall or illuminated wall or illuminated wall or Building facades No allowance surface or 2.5 W/linear surface or 3. 75 W/linear surface or 5.0 W/linear foot for each illuminated foot for each illuminated foot for each illuminated Nontradable Surfaces wall or surface length wall or surface length wall or surface length (Lighting power density Automated teller 270 W per location plus 270 W per location plus 270 W per location plus 270 W per location plus calculations for the following applications machines and night 90 W per additional 90 W per additional 90 W per additional 90 W per additional can be used only for the depositories ATM per location ATM per location ATM per location ATM per location specific application and Entrances and gatehouse cannot be traded between 0.75 W/ft 2 of covered 0.75 W/ft 2 of covered 0.75 W/ft 2 of covered 0.75 W/ft 2 of covered surfaces or with other inspection stations at and uncovered area and uncovered area and uncovered area and uncovered area exterior lighting. The guarded facilities following allowances are Loading areas for law in addition to any enforcement, fire, 0.5 W/ft 2 of covered 0.5 W/ft 2 of covered 0.5 W/ft 2 of covered 0.5 W/ft 2 of covered allowance otherwise ambulance and other permitted in the emergency service and uncovered area and uncovered area and uncovered area and uncovered area "Tradable Surfaces" vehicles section of this table.) Drive-up windows/doors 400 W per drive-through 400 W per drive-through 400 W per drive-through 400 W per drive-through Parking near 24-hour 800 W per main entry 800 W per main entry 800 W per main entry 800 W per main entry retail entrances For SI: 1 foot = 304.8 mm, 1 watt per square foot =W/0.0929 m 2 • 62 2009 INTERNATIONAL ENERGY CONSERVATION CODE® 506.3 Performance-based compliance. Compliance based on total building performance requires that a proposed building (proposed design) be shown to have an annual energy cost that is less than or equal to the annual energy cost of the standard reference design. Energy prices shall be taken from a source approved by the code official, such as the Department of Energy, Energy Information Administration's State Energy Price and Expenditure Report. Code officials shall be permit- ted to require time-of-use pricing in energy cost calculations. Nondepletable energy collected off site shall be treated and priced the same as purchased energy. Energy from nondepletable energy sources collected on site shall be omitted from the annual energy cost of the proposed design. Exception: Jurisdictions that require site energy (1 kWh = 3413 Btu) rather than energy cost as the metric of compari- son. 506.4 Documentation. Documentation verifying that the methods and accuracy of compliance software tools conform to the provisions of this section shall be provided to the code official. 506.4.1 Compliance report. Compliance software tools shall generate a report that documents that the proposed design has annual energy costs less than or equal to the annual energy costs of the standard reference design. The compliance documentation shall include the following information: 1. Address of the building; 2. An inspection checklist documenting the building component characteristics of the proposed design as listed in Table 506.5.1 (1). The inspection checklist shall show the estimated annual energy cost for both the standard reference design and the proposed design; 3. Name of individual completing the compliance report; and 4. Name and version of the compliance software tool. 506.4.2 Additional documentation. The code officialshall be permitted to require the following documents: 1. Documentation of the building component character- istics of the standardreference design; 2. Thermal zoning diagrams consisting of floor plans showing the thermal zoning scheme for standardref- erence design and proposeddesign. 3. Input and output report(s) from the energy analysis simulation program containing the complete input and output files, as applicable. The output file shall include energy use totals and energy use by energy source and end-use served, total hours that space con- ditioning loads are not met and any errors or warning messages generated by the simulation tool as applica- ble; 4. An explanation of any error or warning messages appearing in the simulation tool output; and 2009 INTERNATIONAL ENERGY CONSERVATION CODE® COMMERCIAL ENERGY EFFICIENCY 5. A certification signed by the builder providing the building component characteristics of the proposed design as given in Table 506.5.1 (1). 506.5 Calculation procedure. Except as specified by this sec- tion, the standard reference design and proposed design shall be configured and analyzed using identical methods and tech- niques. 506.5.1 Building specifications. The standard reference design and proposed design shall be configured and ana- lyzed as specified by Table 506.5.1 (1). Table 506.5.1 (1) shall include by reference all notes contained in Table 502.2 (1). 506.5.2 Thermal blocks. The standard reference design and proposeddesign shall be analyzed using identical ther- mal blocks as required in Section 506 .5.1.1, 506.2.2 or 506.5.2.3. 506.5.2.1 HVAC zones designed. Where HVAC zones are defined on HVAC design drawings, each HVAC zone shall be modeled as a separate thermal block. Exception: Different HVAC zones shall be allowed to be combined to create a single thermal block or identical thermal blocks to which multipliers are applied provided: 1. The space use classification is the same throughout the thermal block. 2. All HVAC zones in the thermal block that are adjacent to glazed exterior walls face the same orientation or their orientations are within 45 degrees (0.79 rad) of each other. 3. All of the zones are served by the same HV AC system or by the same kind of HV AC system. 506.5.2.2 HVAC zones not designed. Where HVAC zones have not yet been designed, thermal blocks shall be defined based on similar internal load densities, occu- pancy' lighting, thermal and temperature schedules, and in combination with the following guidelines: 1. Separate thermal blocks shall be assumed for inte- rior and perimeter spaces. Interior spaces shall be those located more than 15 feet (4572 mm) from an exterior wall. Perimeter spaces shall be those located closer than 15 feet (4572 mm) from an exterior wall. 2. Separate thermal blocks shall be assumed for spaces adjacent to glazed exterior walls: a separate zoneshall be provided for each orientation, except orientations that differ by no more than 45 degrees (0.79 rad) shall be permitted to be considered to be the same orientation. Each zoneshall include floor area that is 15 feet (4572 mm) or less from a glazed perimeterwall, exceptthat floor areawithin 15 feet (4572 mm) of glazed perimeter walls having more than one orientation shall be divided proportion- ately between zones. 3. Separate thermal blocks shall be assumed for spaces having floors that are in contact with the 63 COMMERCIAL ENERGY EFFICIENCY ground or exposed to ambient conditions from zones that do not share these features. 4. Separate thermal blocks shall be assumed for spaces having exterior ceiling or roof assemblies from zones that do not share these features. 506.5.2.3 Multifamily residential buildings. Residen- tial spaces shall be modeled using one thermal block per space except that those facing the same orientations are permitted to be combined into one thermal block. Corner units and units with roof or floor loadsshall only be com- bined with units sharing these features. 506.6 Calculation software tools. Calculation procedures used to complywith this section shall be software tools capable of calculating the annual energy consumption of all building elements that differ between the standardreference design and the proposed design and shall include the following capabili- ties. 1. Computer generation of the standard reference design using only the input for the proposeddesign. The calcu- lation procedure shall not allow the user to directly mod- ify the building component characteristics of the standard reference design. 2. Buildingoperation for a full calendaryear (8760 hours). 3. Climate data for a full calendar year (8760 hours) and shall reflect approvedcoincident hourly data for temper- ature, solar radiation, humidity and wind speed for the building location. 4. Ten or more thermal zones. 5. Thermal mass effects. 6. Hourly variations in occupancy, illumination, receptacle loads, thermostat settings, mechanical ventilation, HVAC equipment availability, service hot water usage and any process loads. 7. Part-load performance curves for mechanical equip- ment. 8. Capacity and efficiency correction curves for mechani- cal heating and cooling equipment. 9. Printed code officialinspection checklist listing each of the proposed design component characteristics from Table 506.5.1 (1) determined by the analysis to provide compliance, along with their respective performance rat- ings (e.g., R-value, V-factor, SHGC, HSPF, AFUE, SEER, EF, etc.). 506.6.1 Specific approval. Performance analysis tools meeting the applicable subsections of Section 506 and tested according to ASHRAE Standard 140 shall be permit- ted to be approved. Tools are permitted to be approved based on meeting a specified threshold for a jurisdiction. The code official shall be permitted to approve tools for a specified application or limited scope. 506.6.2 Input values. When calculations require input val- ues not specified by Sections 502, 503, 504 and 505, those input values shall be taken from an approvedsource. 64 2009 INTERNATIONAL ENERGY CONSERVATION CODE® COMMERCIAL ENERGY EFFICIENCY TABLE 506.5.1 (1) SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS BUILDING COMPONENT CHARACTERISTICS STANDARD REFERENCE DESIGN PROPOSED DESIGN The space use classification shall be chosen in accordance with Table 505.5.2 for all areas of the Space use classification Same as proposed building covered by this permit. Where the space use classification for a building is not known, the building shall be categorized as an office building. Type: Insulation entirely above deck As proposed Gross area: same as proposed As proposed Roofs U-factor: from Table 502.1.2 As proposed Solar absorptance: 0. 75 As proposed Emittance: 0.90 As proposed Type: Mass wall if proposed wall is mass; otherwise As proposed steel-framed wall Walls, above-grade Gross area: same as proposed As proposed U-factor: from Table 502.1.2 As proposed Solar absorptance: 0.75 As proposed Emittance: 0.90 As proposed Type: Mass wall As proposed Walls, below-grade Gross area: same as proposed As proposed U-Factor: from Table 502.1.2 with insulation layer on interior As proposed side of walls Type:joist/framed floor As proposed Floors, above-grade Gross area: same as proposed As proposed U-factor: from Table 502.1.2 As proposed Floors, slab-on-grade Type: Unheated As proposed F-factor: from Table 502.1.2 As proposed Type: Swinging As proposed Doors Area: Same as proposed As proposed U-factor: from Table 502.2(1) As proposed Area: As proposed (a) The proposedglazingarea;wherethe proposedglazing area is less than 40 percent of above-grade wall area. (b) 40 percent of above-grade wall area; where the proposed Glazing glazing area is 40 percent or more of the above-grade wall area. U-factor: from Table 502.3 As proposed SHGC: from Table 502.3 except that for climates with no As proposed requirement (NR) SHGC = 0.40 shall be used External shading and PF: None As proposed Area: As proposed (a) The proposed skylight area; where the proposed skylight area is less than 3 percent of gross area of roof assembly. (b) 3 percent of gross area of roof assembly; where the pro- Skylights posed skylightareais 3 percent or more of gross area of roof assembly. U-factor: from Table 502.3 As proposed SHGC: from Table 502.3 except that for climates with no As proposed requirement (NR) SHGC = 0.40 shall be used. The interior lighting power shall be determined in accordance As proposed with Table 505.5.2. Where the occupancy of the building is not Lighting, interior known, the lighting power density shall be 1.0 Watt per square foot (10.73 W/m 2 ) based on the categorization of buildings with unknown space classification as offices. The lighting power shall be determined in accordance with As proposed Lighting, exterior Table 505.6.2. Areas and dimensions of tradable and nontradable surfaces shall be the same as proposed. (continued) 2009 INTERNATIONAL ENERGY CONSERVATION CODE® 65 COMMERCIAL ENERGY EFFICIENCY TABLE 506.5.1 (l)-continued SPECIFICATIONS FOR THE STANDARD REFERENCE AND PROPOSED DESIGNS BUILDING COMPONENT CHARACTERISTICS STANDARD REFERENCE DESIGN PROPOSED DESIGN Receptacle, motor and process loads shall be modeled and estimated based on the space use classification. All end-use load components within and associated with the Internal gains Same as proposed building shall be modeled to include, but not be limited to, the following: exhaust fans, parking garage ventilation fans, exterior building lighting, swimming pool heaters and pumps, elevators, escalators, refrigeration equipment and cooking equipment Operating schedules shall include hourly profiles for daily operation and shall account for variations between weekdays, weekends, holidays and any seasonal operation. Schedules shall model the time-dependent Schedules Same as proposed variations in occupancy, illumination, receptacle loads, thermostat settings, mechanical ventilation, HV AC equipment availability, service hot water usage and any process loads. The schedules shall be typical of the proposed building type as determined by the designer and approved by the jurisdiction. Mechanical ventilation Same as proposed As proposed, in accordance with Section 503.2.5. Fuel type: same as proposed design As proposed Equipment type a : from Tables 506.5.1 (2) and 506.5.1 (3) As proposed Efficiency: from Tables 503.2.3(4) and 503.2.3(5) As proposed Heating systems Capacityb: sized proportionally to the capacities in the proposed As proposed design based on sizing runs, and shall be established such that no smaller number of unmet heating load hours and no larger heating capacity safety factors are provided than in the proposed design. Fuel type: same as proposed design As proposed Equipment type c : from Tables 506.5.1 (2) and 506.5.1 (3) As proposed Efficiency: from Tables 503.2.3(1), 503.2.3(2) and 503.2.3(3) As proposed Capacityb: sized proportionally to the capacities in the proposed As proposed Cooling systems design based on sizing runs, and shall be established such that no smaller number of unmet cooling load hours and no larger cooling capacity safety factors are prOVided than in the proposed deSign. Economizer d : same as proposed, in accordance with Section As proposed 503.4.1. Fuel type: same as proposed As proposed Efficiency: from Table 504.2 As proposed Service water heating Capacity: same as proposed As proposed Where no service water hot water system exists or is specified in the proposed design, no service hot water heating shall be modeled. a. Where no heating system exists or has been specified, the heating system shall be modeled as fossil fuel. The system characteristics shall be identical in both the standard reference design and proposed deSign. b. The ratio betweenthe capacities used in the annual simulations and the capacities determined bysizing runs shall be the same for boththe standard reference deSign and proposed design. c. Where no cooling system exists or no cooling system has been specified, the cooling system shall be modeled as an air-cooled single-zone system, one unit per thermal zone. The system characteristics shall be identical in both the standard reference design and proposed design. d. If an economizeris required in accordance with Table 503.3.1 (1), and if no economizerexists or is specified in the proposed design, then a supply air economizer shall be provided in accordance with Section 503.4.1. 66 2009 INTERNATIONAL ENERGY CONSERVATION CODE® COMMERCIAL ENERGY EFFICIENCY TABLE 506.5.1 (2) HVAC SYSTEMS MAP STANDARD REFERENCE DESIGN HVC SYSTEM TYPE c CONDENSER COOLING HEATING SYSTEM Single-zone Single-zone SOURCE a CLASSIFICATION b Residential System Nonresidential System All Other Electric resistance System 5 System 5 System 1 Water/ground Heat pump System 6 System 6 System 6 Fossil fuel System 7 System 7 System 2 Electric resistance System 8 System 9 System 3 Air/none Heat pump System 8 System 9 System 3 Fossil fuel System 10 System 11 System 4 a. Select "water!ground" if the proposeddesignsystemcondenseriswater or evaporatively cooled; select"air!none" if the condenser is air cooled. Closed-circuitdry coolers shall be considered air cooled. Systems utilizing district cooling shall be treated as if the condenser water type were "water." Ifno mechanical cooling is specified or the mechanical cooling system in the proposed design does not require heat rejection, the system shall be treated as if the condenser water type were "Air." For proposed designs with ground-source or groundwater-source heat pumps, the standard reference design HVAC system shall be water-source heat pump (System 6). b. Select the path that corresponds to the proposed design heat source: electric resistance, heat pump (including air source and water source), or fuel fired. Systems utilizing district heating (steam or hot water) and systems with no heating capability shall be treated as if the heating system type were "fossil fue1." For systems with mixed fuel heating sources, the system or systems that use the secondary heating source type (the one with the smallest total installed output capacity for the spaces served by the system) shall be modeled identically in the standard reference design and the primaryheating source type shall be used to determine standard reference design HVAC system type. c. Select the standard reference design HVAC systemcategory: Thesystem under "single-zone residential system" shall be selected if the HVAC system in the pro- posed design is a single-zonesystemand serves a residentialspace. The system under "single-zone nonresidential system" shall be selected if the HVAC system in the proposed design is a single-zone system and serves other than residential spaces. The system under" all other" shall be selected for all other cases. 2009 INTERNATIONAL ENERGY CONSERVATION CODE® 67 COMMERCIAL ENERGY EFFICIENCY TABLE 506.5.1 (3) SPECIFICATIONS FOR THE STANDARD REFERENCE DESIGN HVAC SYSTEM DESCRIPTIONS SYSTEM NO. SYSTEM TYPE FAN CONTROL COOLING TYPE HEATING TYPE 1 Variable air volume with parallel fan-powered boxes a VAV d Chilled water e Electric resistance 2 Variable air volume with reheat b VAV d Chilled water e Hot water fossil fuel boiler f 3 Packaged variable air volume with parallel fan-powered VAV d Direct expansion c Electric resistance boxes a 4 Packaged variable air volume with reheat b VAV d Direct expansion c Hot water fossil fuel boiler f 5 Two-pipe fan coil Constant volume i Chilled water e Electric resistance 6 Water-source heat pump Constant volume i Direct expansion c Electric heat pump and boiler g 7 Four-pipe fan coil Constant volume i Chilled water e Hot water fossil fuel boiler f 8 Packaged terminal heat pump Constant volume i Direct expansion c Electric heat pumph 9 Packaged rooftop heat pump Constant volume i Direct expansion c Electric heat pumph 10 Packaged terminal air conditioner Constant volume i Direct expansion Hot water fossil fuel boiler f 11 Packaged rooftop air conditioner Constant volume i Direct expansion Fossil fuel furnace For SI: 1 foot = 304.8 mm, 1 cfrnlff= 0.0004719, 1 Btu/h = 0. 293/W, °C = [(OF) -32/1.8] . a. VAV with parallel boxes: Fans in parallel VAV fan-powered boxes shall be sized for 50 percent of the peakdesignflow rate and shall be modeled with 0.35 WIcfm fan power. Minimum volume setpoints for fan-powered boxes shall be equal to the minimum rate for the space required for ventilation consistent with Section 503.4. 5, Exception 5. Supply air temperature setpoint shall be constant at the design condition. b. VAV with reheat: Minimum volume setpoints for VAV reheat boxes shall be 0.4 cfm/ft 2 of floor area. Supply air temperature shall be reset based on zone demand from the design temperature difference to alO°F temperature difference under minimumload conditions.Designairflow rates shall be sized for the reset supplyair temperature, Le., a 10°F temperature difference. c. Direct expansion: The fuel type for the cooling system shall match that of the cooling system in the proposed design. d. YAY: Constant volume can be modeled if the systemqualifies for Exception 1,Section503.4.5. When the proposed designsystem has a supply, return or relieffan motor 25 horsepower (hp) or larger, the corresponding fan in the VAV system of the standard reference design shall be modeled assuming a variable speed drive. For smaller fans,a forward-curved centrifugal fan with inlet vanes shall be modeled. Ifthe proposed design's system has a direct digital control system at the zone level, static pressure setpoint reset based on zone requirements in accordance with Section 503.4.2 shall be modeled. e. Chilled water: For systems using purchased chilled water, the chillers are not explicitly modeled and chilled water costs shall be based as determined in Sections 506.3 and 506.5.2. Otherwise, the standard reference design's chiller plant shall be modeled with chillers having the number as indicatedin Table 506.5.1 (4) as a function of standard reference buildingchillerplantload and type as indicatedinTable 506.5.1 (5) as a function of individual chiller load.Where chillerfuel source is mixed, the system in the standard reference design shall have chillers with the same fuel types and with capacities having the same proportional capacity as the proposed design's chillers for eachfuel type. Chilled water supply temperature shall be modeled at 44°F design supplytemperature and 56°F return temperature. Piping losses shall not be modeled ineitherbuildingmodel. Chilledwatersupplywatertemperatureshall be reset inaccordance with Section 503.4.3.4. Pumpsys- tem power for each pumping system shall be the same as the proposed design; if the proposed design has no chilled water pumps, the standard reference design pump power shall be 22 WIgpm (equal to a pump operating against a 75-foot head, 65-percent combined impeller and motor efficiency). The chilled water system shall be modeled as primary-onlyvariable flow with flow maintained at the design rate througheach chiller using a bypass. Chilledwater pumpsshall be modeled as riding the pump curve or with variable-speed drives when required in Section 503.4.3.4. The heat rejection device shall be an axial fan cooling tower with two-speed fans if required in Section 503.4.4. Condenser waterdesign supply temperature shall be 85°F or 10°Fapproachto design wet-bulb temperature, which- everis lower, with a design temperature rise of 10°F. Thetowershallbe controlled to maintaina 70°F leavingwatertemperaturewhereweatherpermits, floating up to leaving water temperature at design conditions. Pump system power for each pumpingsystemshall be the same as the proposed design; if the proposed design has no condenserwater pumps, the standard reference design pump power shall be 19 W/gpm (equal to a pump operating against a 60-foothead, 60-percent com- bined impellerand motor efficiency). Each chiller shall be modeled with separate condenserwaterand chilled water pumps interlocked to operate with the associ- ated chiller. f. Fossil fuel boiler: Forsystems using purchased hotwater or steam, the boilers are notexplicitlymodeledandhotwater orsteamcostsshall be based onactual util- ity rates. Otherwise, the boiler plant shall use the same fuel as the proposed design and shall be natural draft. The standard reference design boiler plant shall be modeled with a single boiler if the standard reference design plant load is 600,000 Btu/h and less and with two equallysized boilers for plant capacities exceeding 600 , 000 Btu/h. Boilers shall be stagedas reqUired by the load. Hot watersupplytemperatureshall be modeled at 180°Fdesignsupplytemperature and 130°Freturn temperature. Piping losses shall not be modeled in either building model. Hot water supply water temperature shall be reset in accordance with Section 503.4.3.4. Pump system power for each pumping system shall be the same as the proposed design; if the proposed design has no hot water pumps, the standard reference design pump powershall be 19 WIgpm (equal to a pumpoperatingagainst a 60-foot head, 60-percentcombinedimpellerand motorefficiency). The hotwatersys- tem shall be modeled as primary only with continuous variable flow. Hot water pumps shall be modeled as riding the pump curve or with variable speed drives when required by Section 503.4.3.4. g. Electric heat pump and boiler: Water-source heat pumps shall be connected to a common heat pump water loop controlled to maintain temperatures between 60°F and 90°F. Heat rejection from the loop shall be provided by an axial fan closed-circuit evaporative fluid cooler with two-speed fans if required in Section 503.4.2.Heatadditionto the loop shall be provided by a boilerthatuses the same fuel as the proposed design and shall be natural draft. Ifno boilers exist in the pro- posed design,the standardreference building boilers shall be fossil fuel. The standardreference designboilerplantshall be modeled witha single boiler if the stan- dard reference design plant load is 600,000 Btu/h orless and with two equallysized boilers for plant capacities exceeding 600,000 Btu/h. Boilers shall be staged as reqUired by the load. Piping losses shall not be modeled in either building model. Pump system power shall be the same as the proposed design; if the proposed design has no pumps, the standard reference design pump power shall be 22 WIgpm, whichis equal to a pump operatingagainsta 75-foot head, with a 65-percent combined impeller and motor efficiency. Loop flow shall be variable with flow shutoffat each heat pump when its compressor cycles offas reqUired by Section 503.4.3.3. Loop pumps shall be modeled as riding the pump cune or with variable speed drives when reqUired by Section 503.4.3.4. h. Electric heat pump: Electric air-source heat pumps shall be modeled with electric auxiliary heat. The system shall be controlledwitha multistage space thermo- stat and an outdoor air thermostat wired to energize auxiliary heat only on the last thermostat stage and when outdoor airtemperature is less than 40°F. L Constantvolume: Fans shall be controlled in the same manner as inthe proposed design; Le., fan operationwheneverthespaceis occupiedorfan operation cycled oncalls for heatingand cooling.Ifthe fan is modeled as cyclingand the fan energyis included in the energy efficiency rating of the equipment, fan energyshall not be modeled explicitly. 68 2009 INTERNATIONAL ENERGY CONSERVATION CODE® TABLE 506.5.1 (4) NUMBER OF CHILLERS COMMERCIAL ENERGY EFFICIENCY TOTAL CHILLER PLANT CAPACITY NUMBER OF CHILLERS :::; 300 tons 1 > 300 tons, < 600 tons 2, sized equally ~ 600 tons 2 minimum, with chillers added so that no chiller is larger than 800 tons, all sized equally For 51 : 1 ton = 3517 w. TABLE 506.5.1 (5) WATER CHILLER TYPES INDIVIDUAL CHILLER PLANT CAPACITY ELECTRIC CHILLER TYPE FOSSIL FUEL CHILLER TYPE :::; 100 tons Reciprocating Single-effect absorption, direct fired > 100 tons, < 300 tons Screw Double-effect absorption, direct fired ~ 300 tons Centrifugal Double-effect absorption, direct fired For 51 : 1 ton = 3517 w. 2009 INTERNATIONAL ENERGY CONSERVATION CODE® 69 . cyclingand the fan energyis included in the energy efficiency rating of the equipment, fan energyshall not be modeled explicitly. 68 2009 INTERNATIONAL ENERGY CONSERVATION CODE TABLE 506.5.1. 24-hour 80 0 W per main entry 80 0 W per main entry 80 0 W per main entry 80 0 W per main entry retail entrances For SI: 1 foot = 304 .8 mm, 1 watt per square foot =W/0.0929 m 2 • 62 2009 INTERNATIONAL ENERGY. 24-hour retail entrances 80 0 watts per main entry For 51: 1 foot = 304 .8 mm, 1 watt per square foot =W/0.0929 m 2 • 2009 INTERNATIONAL ENERGY CONSERVATION CODE 61 COMMERCIAL ENERGY EFFICIENCY TABLE

Ngày đăng: 08/08/2014, 17:20

Từ khóa liên quan

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan