lecture 5 hplc

6 326 1
lecture 5 hplc

Đang tải... (xem toàn văn)

Thông tin tài liệu

1 High Performance Liquid Chromatography (HPLC) Pham Van Hung, PhD HPLC High Performance Liquid Chromatography (HPLC) A mixture is injected into a “steel-jacketed” chromatography column and eluted with solvent at high pressure (4000psi or approx 130 atm). Elute with solvent UV detector Inject sample as gas or liquid. A solid component can be dissolved in solvent but a solvent peak will also be seen. Retention Time- t R • The elapsed time between the time of analyte injection and the time which the maximum peak height for that compound is detected. • Different compounds will have different retention times. – Each compound will have its own characteristic balance of attraction to the mobile/stationary phase. »So they will not move at the same speed. • Running conditions can also effect t R : – Pressure used, nature of the stationary phase, mobile phase composition, temperature of the column 2 Retention Time Time required for the sample to travel from the injection port through the column to the detector. Response Retention Time 5 10 15 20 25 A B C D Selectivity Ratio of Net Retention Time of 2 components (Distribution Coefficient) X 2 - X 0 X 1 X 0 - α = Response Retention Time X X X 1 3 6 2 1 0 Resolution General Factors Increasing Resolution • Increase column length • Decrease column diameter • Decrease flow-rate • Pack column uniformly • Use uniform stationary phase (packing material) • Decrease sample size • Select proper stationary phase • Select proper mobile phase • Use proper pressure • Use gradient elution 3 Determining Concentration • In most cases, sample peaks on the chromatogram can be used to estimate the amount of a compound present. • The more concentrated, the stronger the signal, the larger the peak. http://www.waters.com/WatersDivision/Contentd.asp?watersit=JDRS-6UXGZ4 Types of HPLC • There are numerous types of HPLC which vary in their separation chemistry. – All chromatographic modes are possible: • Ion-exchange • Size exclusion • Also can vary the stationary & mobile phases: – Normal phase HPLC – Reverse phase HPLC Design & Operation of an HPLC Instrument 1) Mobile phase degassing: • Dissolved gases in the mobile phase can come out of solution and form bubbles as the pressure changes from the column entrance to the exit. – May block flow through the system • Sparging is used to remove any dissolved gas from the mobile phase. – An inert and virtually insoluble gas, such as helium, is forced into the mobile phase solution and drives out any dissolved gas. • Degassing may also be achieved by filtering the mobile phase under a vacuum. Design & Operation of an HPLC Instrument 2) Solvent reservoirs: • Individual reservoirs store the mobile phase components until they are mixed and used. • May also manually prepare the mobile phase mixture and store in a single reservoir. 2. 4 3) Mobile phase mixing: • Solvent proportioning valve can be programmed to mix specific amounts of solvent from the various reservoirs to produce the desired mobile phase composition. Design & Operation of an HPLC Instrument 3. 3) Mobile phase mixing: • Isocratic elution: – operate at a single, constant mobile phase composition • Gradient elution: – Vary the mobile phase composition with time – If there is a wide polarity range of components to be eluted. – Allows for faster runs. – Ex: mobile phase composition can be programmed to vary from 75% water: 25% acetonitrile at time zero to 25% water: 75% acetonitrile at the end of the run. • More polar components will tend to elute first. • More non-polar components will elute later in the gradient. Design & Operation of an HPLC Instrument Design & Operation of an HPLC Instrument 4) HPLC pump: • Fill stroke: mobile phase is pulled from the solvent side • Exhaust stroke: the mobile phase is pushed from the injector to the column head. – This is where the high pressure is generated 4. 5) Injector: • Introduces the sample into the mobile phase stream to be carried into the column. • Syringe = impractical for use in highly pressurized systems. • Rotary injection valve is used. Design & Operation of an HPLC Instrument 5. 5 6) Column: • Usually constructed of stainless steel – glass or Tygon may be used for lower pressur e applications (<600 psi). • Length: 5-100cm – 10 to 20cm common •Diameter: – Typical: 2.1, 3.2, or 4.5mm – Up to 30mm for preparative applications Design & Operation of an HPLC Instrument 6. • Column packing: – Usually spherical silica particles of uniform diameter (2-10µm) • The smaller particles yield higher separation efficiencies. – The silica particles are very porous • Allows for greater surface area for interactions between the stationary phase and the analytes. – Other packing materials may also be used: • Zirconia (ZrO 2 ) http://www.lcresources.com/resources/getstart/3a01.htm Design & Operation of an HPLC Instrument http://hplc.chem.shu.edu/NEW/HP LC_Book/Adsorbents/ads_part.html 6) Column: • Guard column: Protects the analytical column –Particles –Interferences –Prolongs the life of the analytical column • Analytical column : Performs the separation Design & Operation of an HPLC Instrument 7) Detector: • The component that emits a response due to the eluting sample compound and subsequently signals a peak on the chromatogram. • A wide variety of detectors exist. • Must have high sensitivity- small sample sizes are used with most HPLC columns Design & Operation of an HPLC Instrument 7. 6 Detection in HPLC *There are six major HPLC detectors: • Refractive Index (RI) Detector • Evaporative Light Scattering Detector (ELSD) • UV/VIS Absorption Detectors • The Fluorescence Detector • Electrochemical Detectors (ECDs) • Conductivity Detector * The type of detector utilized depends on the characteristics of the analyte of interest. http://www.waters.com/WatersDivision/Contentd.asp?watersit=JDRS-6UXGZ4 What is Ultra Performance Liquid Chromatography? • 2004: Further advances in column technology and chromatography instrumentation – Utilized even smaller packing particle sizes (1.7µm) – Higher pressures (15000psi) – Allowed for significant increases in LC speed, reproducibility, and sensitivity. • New research utilizing particle sizes as small as 1µm and pressures up to 100,000psi! WHO KNOWS WHAT THE FUTURE MAY BRING! LC Application in Food System Carbohydrates Amino acids, proteins Vitamins, A, D, E, K Nucleosides (purines and pyrimidines) Fatty acids, fats Aflatoxins Antioxidants Contaminants of packaging materials Carotenoids, chlorophylls Saccharines The end! . phase composition can be programmed to vary from 75% water: 25% acetonitrile at time zero to 25% water: 75% acetonitrile at the end of the run. • More polar. sizes are used with most HPLC columns Design & Operation of an HPLC Instrument 7. 6 Detection in HPLC *There are six major HPLC detectors: • Refractive

Ngày đăng: 08/03/2014, 15:35

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan