Finite time exergoeconomic performance optimization for an irreversible universal steady flow variable-temperature heat reservoir heat pump cycle model

18 609 0
Finite time exergoeconomic performance optimization for an irreversible universal steady flow variable-temperature heat reservoir heat pump cycle model

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

An irreversible universal steady flow heat pump cycle model with variable-temperature heat reservoirs and the losses of heat-resistance and internal irreversibility is established by using the theory of finite time thermodynamics. The universal heat pump cycle model consists of two heat-absorbing branches, two heat-releasing branches and two adiabatic branches. Expressions of heating load, coefficient of performance (COP) and profit rate of the universal heat pump cycle model are derived, respectively. By means of numerical calculations, heat conductance distributions between hot- and cold-side heat exchangers are optimized by taking the maximum profit rate as objective. There exist an optimal heat conductance distribution and an optimal thermal capacity rate matching between the working fluid and heat reservoirs which lead to a double maximum profit rate. The effects of internal irreversibility, total heat exchanger inventory, thermal capacity rate of the working fluid and heat capacity ratio of the heat reservoirs on the optimal finite time exergoeconomic performance of the cycle are discussed in detail. The results obtained herein include the optimal finite time exergoeconomic performances of endoreversible and irreversible, constant- and variable-temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual, Miller and Carnot heat pump cycles.

INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENT Volume 1, Issue 6, 2010 pp.969-986 Journal homepage: www.IJEE.IEEFoundation.org Finite time exergoeconomic performance optimization for an irreversible universal steady flow variable-temperature heat reservoir heat pump cycle model Huijun Feng, Lingen Chen, Fengrui Sun Postgraduate School, Naval University of Engineering, Wuhan 430033, P R China Abstract An irreversible universal steady flow heat pump cycle model with variable-temperature heat reservoirs and the losses of heat-resistance and internal irreversibility is established by using the theory of finite time thermodynamics The universal heat pump cycle model consists of two heat-absorbing branches, two heat-releasing branches and two adiabatic branches Expressions of heating load, coefficient of performance (COP) and profit rate of the universal heat pump cycle model are derived, respectively By means of numerical calculations, heat conductance distributions between hot- and cold-side heat exchangers are optimized by taking the maximum profit rate as objective There exist an optimal heat conductance distribution and an optimal thermal capacity rate matching between the working fluid and heat reservoirs which lead to a double maximum profit rate The effects of internal irreversibility, total heat exchanger inventory, thermal capacity rate of the working fluid and heat capacity ratio of the heat reservoirs on the optimal finite time exergoeconomic performance of the cycle are discussed in detail The results obtained herein include the optimal finite time exergoeconomic performances of endoreversible and irreversible, constant- and variable-temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual, Miller and Carnot heat pump cycles Copyright © 2010 International Energy and Environment Foundation - All rights reserved Keywords: Finite time thermodynamics, Heating load, COP, Profit rate, Irreversible universal heat pump cycle, Internal irreversibility, Optimal heat capacity rate matching, Exergoeconomic performance Introduction Finite time thermodynamics (FTT) [1-15] has been a powerful tool for the performance analyses and optimizations of various thermodynamic processes and cycles The performance index in the analyses and optimizations are often pure thermodynamic parameters, which include power output, efficiency, entropy production rate, cooling load, heating load, coefficient of performance (COP), exergy loss, etc Exergoeconomic (or thermoeconomic) analysis [16, 17] is a relatively new method that combines exergy with conventional concepts from long-run engineering economic optimization to evaluate and optimize the design and performance of energy systems Salamon and Nitzan’s work [18] combined the endoreversible model in finite time thermodynamics with exergoeconomic analysis It was termed as finite time exergoeconomic analysis [19-36] to distinguish it from the endoreversible analysis with pure thermodynamic objectives and the exergoeconomic analysis with long-run economic optimization This ideal has been extended to endoreversible [19-24] and generalized irreversible [25-27] Carnot heat engines, refrigerators and heat pumps, universal steady flow two-heat-reservoir heat engine, refrigerator ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 970 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 and heat pump cycles [28-31], three-heat-reservoir refrigerator and heat pump cycles [32, 33], endoreversible and irreversible four-heat-reservoir absorption refrigerator [34], as well as endoreversible closed-cycle simple and regenerative gas turbine heat and power cogeneration plants [35, 36] In succession, a new thermoeconomic optimization criterion, thermodynamic output rates (power, cooling load or heating load for heat engine, refrigerator or heat pump) per unit total cost, was put forward by Sahin and Kodal [37-41] It was used to analyze and optimize the performances of endoreversible [37, 38] and irreversible [39, 40] Carnot heat engines [37, 39], refrigerators and heat pumps [38, 40], and three-heat-reservoir absorption refrigerator and heat pump [41] Generalization and unified description of thermodynamic cycle model is an important task of FTT research Finite time exergoeconomic optimization for endoreversible [30] and irreversible [31] universal steady flow heat pump cycles with constant-temperature heat reservoirs have been studied, but practical heat pump cycles are always irreversible ones and with variable-temperature heat reservoirs There are lacks of unified descriptions of exergoeconomic performances for various heat pump cycles with variable-temperature heat reservoirs On the basis of variable-temperature heat reservoir Carnot and Brayton heat pump cycle models [42-45], this paper will build an irreversible universal steady flow heat pump cycle model consisting of two heat-absorbing branches, two heat-releasing branches and two adiabatic branches with variable-temperature heat reservoirs and the losses of heat-resistance and internal irreversibility The major work of this paper is to provide a unified description of the finite time exergoeconomic performance for various irreversible heat pump cycles with variable-temperature heat reservoirs The results obtained herein include the optimal finite time exergoeconomic performance characteristics of end reversible and irreversible variable- and constant-temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual, Miller and Carnot heat pump cycles Cycle model An irreversible universal variable-temperature heat reservoir heat pump cycle model with heat-resistance and internal irreversibility is shown in Figure The following assumptions are made for this model: (1) The working fluid is an ideal gas and flows through the system in a quasi-steady fashion The cycle consists of two heat-absorbing branches (1-2 and 2-3) with constant working fluid thermal capacity rates (mass flow rate of the working fluid and specific heat product) Cwf and Cwf , two heat-releasing branches (4-5 and 5-6) with constant working fluid thermal capacity rates Cwf and Cwf and two adiabatic branches (3-4 and 6-1) All six processes are irreversible (2) The hot- and cold-side heat exchangers are considered to be counter-flow heat exchangers, the working fluid temperatures are different from the heat reservoir temperatures owing to the heat transfer The heat transfer rate ( QH ) released to the heat sink, i.e the heating load of the cycle, and the heat transfer rate ( QL ) supplied by the heat source are: QH = QH + QH (1) QL = QL1 + QL (2) where QH + QH is due to the driving force of temperature differences between the high-temperature (hot-side) heat sink and working fluid, QL1 + QL is due to the driving force of temperature differences between the low-temperature (cold-side) heat source and working fluid The high-temperature heat sink is considered with thermal capacity rate CH and the inlet and outlet temperatures of the heat-releasing fluid are THin , THout1 and THout , respectively The low-temperature heat source is considered with thermal capacity rate CL and the inlet and outlet temperatures of the heat-absorbing fluid are TLin , TLout1 and TLout , respectively (3) A constant coefficient φ is introduced to characterize the additional internal miscellaneous ' ' irreversibility effects: φ = (QH + QH ) / (QH + QH ) ≥ , where QH + QH is the rate of heat-flow from the ' ' warm working-fluid to the heat-sink for the irreversible cycle model, while QH + QH is that for the endoreversible cycle model with the only loss of heat-resistance ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 971 To summarize, the irreversible universal heat pump cycle model with variable-temperature heat reservoirs is characterized by the following three aspects: (1) The different values of CH and CL If CH → ∞ and CL → ∞ , the cycle model is reduced to the irreversible universal heat pump cycle model with constant-temperature heat reservoirs [31] (2) The different values of Cwf , Cwf , Cwf and Cwf If Cwf , Cwf , Cwf and Cwf have different values, the cycle model can be reduced to various special heat pump cycles (3) The different values of φ If φ = , the cycle model is reduced to the endoreversible universal heat pump cycle model with variable-temperature heat reservoirs If φ = , CH → ∞ and CL → ∞ further, the cycle model is reduced to the endoreversible universal heat pump cycle model with constant-temperature heat reservoirs [30] Figure Cycle model According to the properties of heat transfer, heat reservoir, working fluid, and the theory of heat exchangers, the heat transfer rates ( QH and QH ) released to the heat sink and the heat transfer rates ( QL1 and QL ) supplied by heat source are, respectively, given by QH = U H 1[(T5 − THout1 ) − (T6 − THin )] / ln[(T5 − THout1 ) / (T6 − THin )] = CH (THout1 − THin ) = Cwf (T5 − T6 ) = CH 1min EH (T5 − THin ) QH = U H [(T4 − THout ) − (T5 − THout1 )] / ln[(T4 − THout ) / (T5 − THout1 )] = C H (THout − THout1 ) = Cwf (T4 − T5 ) = C H EH (T4 − THout1 ) QL1 = U L1[(TLout1 − T2 ) − (TLout − T1 )] / ln[(TLout1 − T2 ) / (TLout − T1 )] = CL (TLout1 − TLout ) = Cwf (T2 − T1 ) = CL1min EL1 (TLout1 − T1 ) QL = U L [(TLin − T3 ) − (TLout1 − T2 )] / ln[(TLin − T3 ) / (TLout1 − T2 )] = CL (TLin − TLout1 ) = Cwf (T3 − T2 ) = CL EL (TLin − T2 ) (3) (4) (5) (6) where EH , EH , EL1 and EL are the effectivenesses of the hot- and cold-side heat exchangers, and are defined as: EH = {1 − exp[− N H (1 − CH 1min / CH 1max )]} / {1 − (CH 1min / CH 1max ) exp[− N H (1 − CH 1min / CH 1max )]} (7) ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 972 EH = {1 − exp[− N H (1 − CH / CH max )]} / {1 − (CH / CH max ) exp[− N H (1 − CH / CH max )]} (8) EL1 = {1 − exp[− N L1 (1 − CL1min / CL1max )]} / {1 − (CL1min / CL1max ) exp[− N L1 (1 − CL1min / CL1max )]} (9) EL = {1 − exp[− N L (1 − CL / CL max )]} / {1 − (CL / CL max ) exp[− N L (1 − CL / CL max )]} (10) where CH 1min and CH 1max are the minimum and maximum of CH and Cwf , respectively; CH and CH max are the minimum and maximum of CH and Cwf , respectively; CL1min and CL1max are the minimum and maximum of CL and Cwf , respectively; CL and CL max are the minimum and maximum of CL and Cwf , respectively; and N H , N H , N L1 and N L are the numbers of heat transfer units of the hot- and cold-side heat exchangers, respectively: CH 1min = min{CH , Cwf } , CH 1max = max{CH , Cwf } (11) CH = min{CH , Cwf } , CH max = max{CH , Cwf } (12) CL1min = min{CL , Cwf 1} , CL1max = max{CL , Cwf 1} (13) CL = min{CL , Cwf } , CL max = max{CL , Cwf } (14) N H = U H / CH 1min , N H = U H / CH , N L1 = U L1 / CL1min , N L = U L / CL (15) where U H , U H , U L1 and U L are the heat conductances, that is, the product of heat transfer coefficient α and heat transfer surface area F Finite time exergoeconomic performance analysis Combining equations (3)-(6), one can obtain: T5 = ( Cwf 3T6 − C H 1min EH 1THin ) ( Cwf − C H 1min EH ) T4 = [CH 1min CH Cwf E H 1E H (−T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + Cwf (Cwf 4T6 − CH E H 2THin )] [(Cwf − CH 1min E H )(Cwf − CH E H )] T1 = [CL1min CL Cwf E L1E L (TLin − T3 ) CL + CL1min E L1TLin (CL E L − Cwf ) + Cwf (Cwf 2T3 − CL E L 2TLin )] / [(Cwf − CL1min E L1 )(Cwf − CL E L )] T2 = ( Cwf 2T3 − C L EL 2TLin ) ( Cwf − C L EL ) (16) (17) (18) (19) The second law of thermodynamics requires that: ' ' φ = (QH + QH ) (QH + QH ) = (Cwf ln T5 T T T + Cwf ln ) (Cwf ln + Cwf ln ) T6 T5 T1 T2 (20) Thus: T2 = T1G (21) where: ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 Cwf G=x φ Cwf − y 973 Cwf Cwf Cwf ⎧[CH 1min CH Cwf E H 1E H (−T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + ⎫φ Cwf ⎪ ⎪ ⎨ ⎬ Cwf (Cwf 4T6 − CH E H 2THin )] [(Cwf 3T6 − CH 1min EH 1THin )(Cwf − CH E H )] ⎪ ⎪ ⎩ ⎭ (22) where x = T5 T6 and y = T3 T2 Combining equations (3)-(6) with equations (18)-(22) gives: T1 = T2 = T3 = CL1min E L1TLin [CL Cwf E L + CL (−Cwf + CL E L )] GyCL1min CL Cwf E L1E L − CL [Cwf (G − 1) + CL1min E L1 ](Cwf − CL E L ) GCL1min E L1TLin [CL Cwf E L + CL (−Cwf + CL E L )] GyCL1min CL Cwf E L1E L − CL [Cwf (G − 1) + CL1min E L1 ](Cwf − CL E L ) GyCL1min E L1TLin [CL Cwf E L + CL (−Cwf + CL E L )] GyCL1min CL Cwf E L1E L − CL [Cwf (G − 1) + CL1min E L1 ](Cwf − CL E L ) (23) (24) (25) THout = [CH THin (Cwf − CH 1min E H )(Cwf − CH E H ) + CH 1min CH Cwf 3Cwf E H E H ( −T6 + THin ) + CH Cwf (T6 − THin )(CH Cwf E H + CH 1min E H 1Cwf − CH 1min CH E H E H ) ] / (26) [C (Cwf − CH 1min E H )(Cwf − CH E H )] H TLout = {CL1min CL Cwf 1Cwf E L1E L 2TLin [(G − 1)Cwf + (1 − Gy )CL1min E L1 ] + CL TLin (Cwf − CL1min E L1 )(Cwf 1G + CL1min E L1 − Cwf )(Cwf − CL E L ) + 2 CL Cwf 2TLin [(1 − G )CL Cwf 1E L + CL1min E L1 (Cwf 1Gy + CL E L − Cwf ) + (1 − G )Cwf 1CL1min Cwf 1E L1 + (G − 2)CL E L CL1min Cwf 1E L1 ]} / (27) {(Cwf 1CL − CL1min CL E L1 )[−GyCL1min CL Cwf E L1E L + CL (Cwf 1G + CL1min E L1 − Cwf )(Cwf − CL E L )]} Substituting equations (3), (4), (16) and (17) into equation (1) yields the heating load of the cycle: QH = QH + QH = [−CH 1min CH Cwf 3Cwf E H 1E H (T6 − THin ) / CH + CH Cwf 3Cwf E H (T6 − THin ) + (28) CH 1min E H 1Cwf (T6 − THin )(Cwf − CH E H )] / [(Cwf − CH 1min E H )(Cwf − CH E H )] Substituting equations (5), (6), (18) and (19) into equation (2) yields the heat transfer rate supplied by the heat source: QL = QL1 + QL 2 = TLin {CL E L (1 − CL1min E L1 / CL )[−G ( y − 1)CL1min Cwf E L1 / CL − (G − 1)(Cwf − CL1min E L1 )] + CL E L [CL1min Cwf E L1 (Cwf + CL1min E L1G − CL1min E L1Gy − Cwf 1G ) / CL + (29) (G − 1)(Cwf 1Cwf − Cwf 1CL1min E L1 − Cwf CL1min E L1 )] + (G − 1)CL1min Cwf 1Cwf E L1}/ [(Cwf 1G + CL1min E L1 − Cwf )(Cwf − CL E L ) − GyCL1min CL Cwf E L1E L / CL ] Combining equations (28) with (29) gives the COP of the cycle: ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 974 β= QH QH = P QH − QL [−CH 1min CH Cwf 3Cwf E H 1E H (T6 − THin ) / CH + CH Cwf 3Cwf E H (T6 − THin ) + CH 1min E H 1Cwf (T6 − THin )(Cwf − CH E H )] / [(Cwf − CH 1min E H )(Cwf − CH E H )] = [−CH 1min CH Cwf 3Cwf E H 1E H (T6 − THin ) / CH + CH Cwf 3Cwf E H (T6 − THin ) + CH 1min E H 1Cwf (T6 − THin )(Cwf − CH E H )] / [(Cwf − CH 1min E H )(Cwf − CH E H )] − (30) 2 TLin {CL E L (1 − CL1min E L1 / CL )[−G ( y − 1)CL1min Cwf E L1 / CL − (G − 1)(Cwf − CL1min E L1 )] + CL E L [CL1min Cwf E L1 (Cwf + CL1min E L1G − CL1min E L1Gy − Cwf 1G ) / CL + (G − 1)(Cwf 1Cwf − Cwf 1CL1min E L1 − Cwf CL1min E L1 )] + (G − 1)CL1min Cwf 1Cwf E L1}/ [(Cwf 1G + CL1min E L1 − Cwf )(Cwf − CL E L ) − GyCL1min CL Cwf E L1E L / CL ] where THout and TLout are calculated by equations (26) and (27) Assuming that the environmental temperature is T0 , the exergy output rate of the cycle is: A=∫ THout THin CH (1 − T0 T )dT − ∫ TLout TLin CL (T0 T − 1)dT (31) = QH − QL − T0 [CH ln(THout THin ) + CL ln (TLout TLin )] = QHη1 − QLη2 where η1 = − T0 / [(THout − THin ) / ln(THout / THin )] , and η = − T0 / [(TLin − TLout ) / ln(TLin / TLout )] Assuming that the prices of exergy output rate and power input are ψ and ψ , the profit rate of the cycle is: Π = ψ A −ψ P = (ψ 1η1 −ψ )QH + (ψ −ψ 1η )QL (32) Substituting equations (28) and (29) into equation (32) yields the profit rate of the cycle: Π = (ψ 1η1 −ψ )[−CH 1min CH Cwf 3Cwf E H 1E H (T6 − THin ) / CH + CH Cwf 3Cwf E H (T6 − THin ) + CH 1min E H 1Cwf (T6 − THin )(Cwf − CH E H )] / [(Cwf − CH 1min E H )(Cwf − CH E H )] + 2 TLin (ψ −ψ 1η ){CL E L (1 − CL1min E L1 / CL )[−G ( y − 1)CL1min Cwf E L1 / CL − (G − 1)(Cwf − CL1min E L1 )] + CL E L [CL1min Cwf E L1 (−Cwf 1G + Cwf + CL1min E L1G − CL1min E L1Gy ) / CL + (33) (G − 1)(Cwf 1Cwf − Cwf 1CL1min E L1 − Cwf CL1min E L1 )] + (G − 1)CL1min Cwf 1Cwf E L1}/ [ (Cwf 1G + CL1min E L1 − Cwf )(Cwf − CL E L ) − GyCL1min CL Cwf E L1E L / CL ] In order to make the cycle operate normally, state point must be between state points and 3, and state point must be between state points and Therefore, the ranges of x and y are: ≤ x ≤ [CH 1min CH Cwf E H 1E H (−T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + Cwf (Cwf 4T6 − CH E H 2THin )] [T6 (Cwf − CH 1min E H )(Cwf − CH E H )] Cwf 1≤ y ≤ x φ Cwf (34) Cwf ⎧[CH 1minCH minCwf 3E H 1E H (−T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + ⎫φ Cwf ⎪ ⎪ ⎨ ⎬ Cwf (Cwf 4T6 − CH E H 2THin )] [(Cwf 3T6 − CH EH 1THin )(Cwf − CH E H )] ⎪ ⎪ ⎩ ⎭ (35) Note that for the process to be potential profitable, the following relationship must exist: < ψ ψ < , because one unit of work input must give rise to at least one unit of exergy output When the price of exergy output rate becomes very large compared with the price of the power input, i.e.ψ ψ → , equation (32) becomes: ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 Π = ψ1 A 975 (36) where A is the exergy output rate of the irreversible universal heat pump cycle That is, the profit rate maximization approaches the exergy output rate maximization When the price of exergy output rate approaches the price of the power input, i.e ψ ψ → , equation (32) becomes Π = −ψ 1T0 [CH ln(THout THin ) + CL ln (TLout TLin )] = −ψ 1T0σ (37) where σ = CH ln(THout THin ) + CL ln (TLout TLin ) is the entropy production rate of the irreversible universal heat pump cycle That is, the profit rate maximization approaches the entropy production rate minimization, i.e., the minimum exergy loss Discussion Equations (30) and (33) are generalized If CH , CL and φ have different values, equations (30) and (33) can be simplified into the corresponding analytical formulae for various endoreversible and irreversible, constant- and variable-temperature heat reservoir heat pump cycles Figure shows the finite time exergoeconomic performance characteristics of the irreversible universal heat pump cycle with variable-temperature heat reservoirs Heat conductances of the hot- and cold-side heat exchangers are set as U H = , U L = and U H = U L1 = kW / K for Brayton, Otto, Diesel and Atkinson heat pump cycles; U H = U H = U L1 = kW / K and U L = for Dual heat pump cycle; U H = and U H = U L1 = U L = kW / K for Miller heat pump cycle, respectively Internal irreversibility and price ratio are set as φ = 1.1 and ψ ψ = , respectively One can continue to discuss the special cases of the universal heat pump cycle for different thermal capacity rates of the working fluid ( Cwf , Cwf , Cwf and Cwf ) in detail, whose dimensionless profit rate versus COP curves are also shown in Figure Figure Π vs β characteristics of irreversible universal heat pump cycle with variable-temperature heat reservoirs & & (1) When Cwf = Cwf = mC p (mass flow rate m of the working fluid and constant pressure specific heat & C p product) and Cwf = Cwf = mC p , U H = , U L = and x = y = , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Brayton heat pump cycle with the losses of heat-resistance and internal irreversibility ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 976 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 & & (2) When Cwf = Cwf = mCv (mass flow rate m of the working fluid and constant volume specific heat Cv & product) and Cwf = Cwf = mCv , U H = , U L = and x = y = , equations (30) and (33) become the COP and finite time exergoeconomic performance of an irreversible variable-temperature heat reservoir steady flow Otto heat pump cycle with the losses of heat-resistance and internal irreversibility & & (3) When Cwf = Cwf = mCv and Cwf = Cwf = mC p , U H = , U L = and x = y = , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Diesel heat pump cycle with the losses of heat-resistance and internal irreversibility & & (4) When Cwf = Cwf = mC p and Cwf = Cwf = mCv , U H = , U L = and x = y = , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Atkinson heat pump cycle with the losses of heatresistance and internal irreversibility & & & (5) When Cwf = Cwf = mCv , Cwf = mCv and Cwf = mC p , U H ≠ , U H ≠ , U L = and y = , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Dual heat pump cycle with the losses of heatresistance and internal irreversibility If U H → , U L = and x = y = further, the Dual heat pump cycle is close to the Diesel heat pump cycle If U H → , U L = and y = further, the Dual heat pump cycle is close to the Otto heat pump cycle In this case, the range of x becomes: ≤ x ≤ [CH 1min CH Cwf E H 1E H (−T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + Cwf (Cwf 4T6 − CH E H 2THin )] [T6 (Cwf − CH 1min E H )(Cwf − CH E H )] (38) and the value of x is given by: x = T5 / T6 = [CH 1min CH Cwf E H 1E H ( −T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + Cwf (Cwf 4T6 − CH E H 2THin )] [(Cwf 3T6 − CH 1min EH 1THin )(Cwf − CH E H )] (39) & & & (6) When Cwf = mC p , Cwf = mCv and Cwf = Cwf = mCv , U H = , U L1 ≠ , U L ≠ and x = , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Miller heat pump cycle with the losses of heat-resistance and internal irreversibility If U H = , U L → and x = y = further, the Miller heat pump cycle is close to the Atkinson heat pump cycle If U H = , U L1 → and x = further, the Miller heat pump cycle is close to the Otto heat pump cycle In this case, the range of y is: ⎧[CH 1min CH Cwf E H 1E H ( −T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + ⎫φ ⎪ ⎪ 1≤ y ≤ ⎨ ⎬ Cwf (Cwf 4T6 − CH E H 2THin )] [(Cwf 3T6 − CH EH 1THin )(Cwf − CH E H )] ⎪ ⎪ ⎩ ⎭ (40) Combining equations (18), (19) and (22) give the following equation that the working fluid temperature T3 should satisfy: (Cwf − CL1min E L1 )(Cwf 2T3 − CL EL 2TLin )[T3 (Cwf − CL EL ) / (Cwf 2T3 − CL EL 2TLin )]k / [CL1min CL Cwf E L1E L (TLin − T3 ) CL + CL1min E L1TLin (CL E L − Cwf ) + Cwf (Cwf 2T3 − CL E L 2TLin )] = ⎧[CH 1min CH Cwf E H 1E H (−T6 + THin ) / CH + CH 1min E H 1THin (−Cwf + CH E H ) + ⎫ ⎪ ⎪ ⎨ ⎬ ⎪ Cwf (Cwf 4T6 − CH E H 2THin )] [(Cwf 3T6 − CH 1min EH 1THin )(Cwf − CH E H )] ⎪ ⎩ ⎭ (41) φk ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 977 where k is the ratio of the specific heats Moreover, combining equations (18), (19), (21) with equation (41) gives G and y (7) When Cwf = Cwf = Cwf = Cwf → ∞ , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Carnot heat pump cycle with the losses of heat-resistance and internal irreversibility Specially, if CH → ∞ and CL → ∞ further, the finite time exergoeconomic performance characteristic of an irreversible Carnot heat pump cycle with variable-temperature heat reservoirs become the finite time exergoeconomic performance characteristics of endoreversible ( φ = ) [21, 24] and irreversible ( φ > ) [28] Carnot heat pump cycle with constant-temperature heat reservoirs, respectively Finite time exergoeconomic performance optimization 5.1 Optimal distributions of heat conductance If heat conductances of hot- and cold-side heat exchangers are changeable, the profit rate of the irreversible universal heat pump cycle may be optimized by searching the optimal heat conductance distributions for the fixed total heat exchanger inventory For the fixed heat exchanger inventory U T , that is, for the constraint of U H + U H + U L1 + U L = U T , defining the distributions of heat conductance uH = U H / U T , uH = U H / U T , uL1 = U L1 / U T and uL = U L / U T leads to: U H = u H 1U T , U H = u H 2U T , U L1 = u L1U T , U L1 = u L1U T , U L = u L 2U T (42) The following conditions should be satisfied: ≤ uH ≤ , ≤ uH ≤ , ≤ uL1 ≤ , ≤ uL ≤ , and u H + u H + u L1 + u L = Moreover, heat conductance distributions are set as uH = and uL = for Brayton, Otto, Diesel and Atkinson heat pump cycles; uL = for Dual heat pump cycle; uH = for Miller heat pump cycle, respectively To illustrate the preceding analyses, one can take the irreversible Brayton heat pump cycle with variabletemperature heat reservoirs (air as the working fluid) as a numerical example In the calculations, it is set that THin = 290.0K , TLin = 268.0K , CH = CL = 1.2 kW / K , Cv = 0.7165kJ / (kg ⋅ K ) , C p = 1.0031kJ / (kg ⋅ K ) , & k = 1.4 , φ = 1.1 , U T = kW / K , m = 1.1165kg / s and ψ / ψ = If there are no special explanations, the parameters are set as above The working fluid temperature T6 is a variable and its reasonable value is greater than THin The calculations illustrate that the values of x and y are always in their ranges The & dimensionless profit rate is defined as Π = Π (0.9mTL CVψ ) Figure shows the effect of the price ratio (ψ ψ ) on the dimensionless profit rate ( Π ) versus COP ( β ) for irreversible variable-temperature heat reservoir Brayton heat pump cycle From Figure 3, one can see that Π increases with the increase in ψ ψ for the fixed β Moreover, when ψ ψ = , the maximum profit rate is not greater than zero, i.e., the heat pump is not profitable regardless of any working condition The dimensionless profit rate ( Π ) versus COP ( β ) and the hot-side heat conductance distribution ( uH ) of an irreversible variable-temperature heat reservoir Brayton heat pump cycle with ψ ψ = and φ = 1.1 is shown in Figure It indicates that the curve of dimensionless profit rate versus hot-side heat conductance distribution is a parabolic-like one for the fixed COP There exists an optimal heat conductance distribution ( uH 2,opt ,Π ) which leads to the optimal dimensionless profit rate ( Π opt , u ) For Otto, Diesel and Atkinson heat pump cycles, the three-dimensional diagram characteristics among dimensionless profit rate versus COP and heat conductance distribution are similar with those shown in Figure The three-dimensional diagram among the dimensionless profit rate ( Π ) and heat conductance distributions ( uH and uH ) of an irreversible variable-temperature heat reservoir Dual heat pump cycle with β = , ψ ψ = and φ = 1.1 is shown in Figure It indicates that there exists a pair of uH 1,opt , Π near zero and uH 2, opt ,Π near 0.5 , which lead to the optimal dimensionless profit rate In this case, Dual heat pump cycle becomes Diesel heat pump cycle The three-dimensional diagram among the dimensionless ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 978 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 profit rate ( Π ) and heat conductance distributions ( uL1 and uL ) of an irreversible variable-temperature heat reservoir Miller heat pump cycle with β = , ψ ψ = and φ = 1.1 is shown in Figure It indicates that there exists a pair of u L1, opt , Π near 0.5 and u L 2, opt , Π near zero, which lead to the optimal dimensionless profit rate In this case, Miller heat pump cycle becomes Atkinson heat pump cycle Figure show the optimal heat conductance distribution ( uH 2,opt ,Π ) versus COP ( β ) for Brayton, Otto, Diesel and Atkinson heat pump cycles It indicates that u H 2, opt , Π is a little greater than 0.5 for Brayton, Otto, Diesel and Atkinson heat pump cycles, and the COP has little effects on u H 2, opt , Π Moreover, when carrying out heat conductance optimizations, u H 2, opt , Π for Dual heat pump cycle and uL 2,opt ,Π for Miller heat pump cycle are close to the corresponding optimal heat conductance distributions of Diesel and Atkinson heat pump cycles as shown in Figures and 6, respectively Figure Effect of ψ / ψ on Π vs β characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle Figure Π vs β and uH for irreversible variable-temperature heat reservoir Brayton heat pump cycle ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 979 Figure Π vs uH and uH for irreversible variable-temperature heat reservoir Dual heat pump cycle Figure Π vs uL1 and uL for irreversible variable-temperature heat reservoir Miller heat pump cycle Figure u H opt , Π vs β for irreversible variable-temperature heat reservoir Brayton, Otto, Diesel and Atkinson heat pump cycles ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 980 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 5.2 Optimal finite time exergoeconomic performance Figure shows the optimal dimensionless profit rate ( Π opt , u ) versus COP ( β ) characteristic for irreversible variable-temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual and Miller heat pump cycles with ψ ψ = and φ = 1.1 It indicates that Π opt , u decreases with the increase in β Dual and Diesel, Miller and Atkinson heat pump cycles have the same optimal dimensionless profit rate versus COP characteristics, respectively For the fixed β , Brayton heat pump cycle has the maximum Π opt , u among the six heat pump cycles, and Otto heat pump cycle has the minimum Figure Π opt , u vs β characteristics for six heat pump cycles Figures 9-11 show the effect of internal irreversibility ( φ ), total heat exchanger inventory ( U T ) and thermal capacity rate of the working fluid ( Cwf ) on the optimal dimensionless profit rate ( Π opt ,u ) versus COP ( β ) characteristics of an irreversible variable-temperature heat reservoir Brayton heat pump cycle with ψ ψ = and CH = CL = 1.2 kW / K , respectively From Figure 9, one can see that for the fixed COP, Π opt ,u decreases with the increase in φ Moreover, when φ = , Π opt ,u versus β characteristic of an irreversible Brayton heat pump cycle with variable-temperature heat reservoirs becomes that of an endoreversible one From Figure 10, one can see that Π opt ,u increases with the increase of U T for the fixed β , but the increment decreases gradually From Figure 11, one can see that Π opt ,u increases with the increase of Cwf when Cwf is lower than CH and CL ; Π opt ,u decreases with the increase of Cwf when Cwf is greater than CH and CL Moreover, the effects of internal irreversibility, total heat exchanger inventory and thermal capacity rate of the working fluid on the optimal finite time exergoeconomic performances of Otto, Diesel, Atkinson, Dual and Miller heat pump cycles are similar with those shown in Figures 9-11 ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 981 Figure Effect of φ on Π opt , u vs β characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle Figure 10 Effect of U T on Π opt , u vs β characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle Figure 11 Effect of Cwf on Π opt , u vs β characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 982 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 5.3 Optimal thermal capacity rate matching between the working fluid and heat reservoirs Figure 12 shows a three-dimensional diagram among the dimensionless profit rate ( Π ), thermal capacity rate matching ( c = Cwf / CL ) between the working fluid and heat reservoirs and heat conductance distribution ( uH ) of an irreversible variable-temperature heat reservoir Brayton heat pump cycle with β = , ψ ψ = and φ = 1.1 From Figure 12, one can see that the curve of Π versus c is a paraboliclike one for the fixed uH There exist an optimal thermal capacity rate matching ( copt ) between the working fluid and heat reservoirs and an optimal heat conductance distribution ( uH 2, opt ) which lead to the double maximum dimensionless profit rate Figures 13-15 show the effect of internal irreversibility ( φ ), total heat exchanger inventory ( U T ) and heat capacity ratio of the heat reservoirs ( CH / CL ) on the optimal dimensionless profit rate ( Π opt ,u ) versus thermal capacity rate matching ( c ) between the working fluid and heat reservoirs characteristics of an irreversible variable-temperature heat reservoir Brayton heat pump cycle with ψ ψ = , respectively From Figure 13, for the fixed c , Π opt ,u decreases with the increase in φ Moreover, when φ = , Π opt ,u versus c characteristic of an irreversible Brayton heat pump cycle with variable-temperature heat reservoirs becomes that of an endoreversible one From Figure 14, one can see that Π opt ,u increases with the increase in U T for the fixed c , but the increment decreases gradually From Figure 15, one can see that when CH / CL = , the optimal thermal capacity rate matching between the working fluid and heat reservoirs is copt = , which leads to the double maximum dimensionless profit rate Meanwhile, copt increases with the increase in CH / CL Moreover, the effects of internal irreversibility, total heat exchanger inventory and heat capacity ratio of the heat reservoirs on the optimal finite time exergoeconomic performances of Otto, Diesel, Atkinson, Dual and Miller heat pump cycles are similar with those shown in Figures 13-15 Figure 12 Π vs c and uH for irreversible variable-temperature heat reservoir Brayton heat pump cycle ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 983 Figure 13 Effect of φ on Π opt , u vs c characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle Figure 14 Effect of U T on Π opt , u vs c characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle Figure 15 Effect of CH / CL on Π opt , u vs c characteristic for irreversible variable-temperature heat reservoir Brayton heat pump cycle ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 984 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 Conclusion Finite time exergoeconomic performance of an irreversible universal steady flow heat pump cycle model with variable-temperature heat reservoirs, and the losses of heat transfer and internal irreversibility is analyzed and optimized by using the theory of finite time thermodynamics Expressions for COP and profit rate are derived and are used to discuss the optimal finite time exergoeconomic performance of the universal heat pump cycle Numerical examples show that the optimal hot-side heat conductance distributions are a little greater than 0.5 for Brayton, Otto, Diesel and Atkinson heat pump cycles; optimal performances of Dual and Miller heat pump cycles are close to those of Diesel and Atkinson heat pump cycles, respectively There exist an optimal heat conductance distribution and an optimal thermal capacity rate matching between the working fluid and heat reservoirs which lead to the double maximum profit rate Moreover, the effects of internal irreversibility, total heat exchanger inventory, thermal capacity rate of the working fluid and heat capacity ratio of the heat reservoirs on the optimal finite time exergoeconomic performance and optimal thermal capacity rate matching between the working fluid and heat reservoirs are discussed The results obtained herein include the optimal finite time exergoeconomic performance of endoreversible and irreversible, constant- and variable- temperature heat reservoir Brayton, Otto, Diesel, Atkinson, Dual, Miller and Carnot heat pump cycles, and can provide some theoretical guidelines for parameter designs and performance optimizations of various practical heat pumps Acknowledgements This paper is supported by The National Natural Science Foundation of P R China (Project No 10905093), The Program for New Century Excellent Talents in University of P R China (Project No NCET-04-1006) and The Foundation for the Author of National Excellent Doctoral Dissertation of P R China (Project No 200136) References [1] Novikov II The efficiency of atomic power stations (A review) Atommaya Energiya 3, 1957(11): 409 [2] Chambdal P Les Centrales Nucleases Paris: Armand Colin, 1957(11): 41-58 [3] Curzon F L, Ahlborn B Efficiency of a Carnot engine at maximum power output Am J Phys., 1975, 43(1): 22-24 [4] Andresen B Finite-Time Thermodynamics Physics Laboratory , University of Copenhagen, 1983 [5] Andresen B, Salamon P and Berry R S Thermodynamics in finite time Phys Today, 1984 (Sept.): 62-70 [6] Andresen B, Berry R S, Ondrechen M J, Salamon P Thermodynamics for processes in finite time Acc Chem Res 1984, 17(8): 266-271 [7] Sieniutycz S, Shiner J S Thermodynamics of irreversible processes and its relation to chemical engineering: Second law analyses and finite time thermodynamics J Non-Equilib Thermodyn., 1994, 19(4): 303-348 [8] Bejan A Entropy generation minimization: The new thermodynamics of finite-size device and finite-time processes J Appl Phys., 1996, 79(3): 1191-1218 [9] Feidt M Thermodynamique et Optimisation Energetique des Systems et Procedes (2nd Ed.) Paris: Technique et Documentation, Lavoisier, 1996 [10] Hoffmann K H, Burzler J M and Schubert S Endoreversible Thermodynamics J Non-Equilib Thermodyn., 1997, 22(4): 311-355 [11] Berry R S, Kazakov V A, Sieniutycz S, Szwast Z, Tsirlin A M Thermodynamic Optimization of Finite Time Processes Chichester: Wiley, 1999 [12] Chen L, Wu C, Sun F Finite time thermodynamic optimization or entropy generation minimization of energy systems J Non-Equilib Thermodyn., 1999, 24(4): 327-359 [13] Sieniutycz S Thermodynamic limits on production or consumption of mechanical energy in practical and industry systems Progress Energy & Combustion Sci., 2003, 29(3): 193-246 [14] Feidt M Optimal use of energy systems and processes Int J Exergy, 2008, 5(5/6): 500-531 [15] Sieniutycz S, Jezowski J Energy Optimization in Process Systems Oxford: Elsevier, 2009 [16] Tsatsaronts G Thermoeconomic analysis and optimization of energy systems Progress Energy & Combustion Sci., 1993, 19(3): 227-257 ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 985 [17] El-Sayed M Y The Thermoeconomics of Energy Conversion London: Elsevier, 2003 [18] Salamon P, Nitzan A Finite time optimizations of a Newton's law Carnot cycle J Chem Phys., 1981, 74(6): 3546-3560 [19] Chen L, Sun F and Chen W Finite time exergoeconomic performance bound and optimization criteria for two-heat-reservoir refrigerators Chinese Sci Bull., 1991, 36(2): 156-157 (in Chinese) [20] Chen L, Sun F, Wu C Exergoeconomic performance bound and optimization criteria for heat engines Int J Ambient Energy, 1997, 18(4): 216-218 [21] Chen L, Sun F The maximum profit rate characteristic of Carnot heat pump Practice Energy Source, 1993(3): 29-30 (in Chinese) [22] Wu C, Chen L, Sun F Effect of heat transfer law on finite time exergoeconomic performance of heat engines Energy, The Int J., 1996, 21(12): 1127-1134 [23] Chen L, Wu C, Sun F Effect of heat transfer law on finite time exergoeconomic performance of a Carnot refrigerator Exergy, An Int J., 2001, 1(4): 295-302 [24] Wu C, Chen L, Sun F Effect of heat transfer law on finite time exergoeconomic performance of a Carnot heat pump Energy Convers Mgmt., 1998, 39(7): 579-588 [25] Chen L, Sun F, Wu C Maximum profit performance for generalized irreversible Carnot engines Appl Energy, 2004, 79(1): 15-25 [26] Chen L, Zheng Z, Sun F, Wu C Profit performance optimization for an irreversible Carnot refrigeration cycle Int J Ambient Energy, 2008, 29(4): 197-206 [27] Chen L, Zheng Z, Sun F Maximum profit performance for a generalized irreversible Carnot heat pump cycle Termotehnica, 2008, 12(2): 22-26 [28] Zheng Z, Chen L, Sun F, Wu C Maximum profit performance for a class of universal steady flow endoreversible heat engine cycles Int J Ambient Energy, 2006, 27(1): 29-36 [29] Kan X, Chen L, Sun F, Wu F Exergoeconomic performance optimization for a steady flow endoreversible refrigerator cycle model including five typical cycles Int J Low-Carbon Tech., 2010, 5(2), 74-80 [30] Feng H, Chen L, Sun F Finite time exergoeconomic performance optimization for a universal steady flow endoreversible heat pump model Int J Low-Carbon Tech., 2010, 5(2), 105-110 [31] Feng H, Chen L, Sun F Finite time exergoeconomic performance optimization for a universal steady flow irreversible heat pump model Int J Sustainable Energy, 2010, in press [32] Chen L, Sun F, Wu C Maximum profit performance of an absorption refrigerator Int J Energy, Environment, and Economics, 1996, 4(1): 1-7 [33] Chen L, Wu C, Sun F, Cao S Maximum profit performance of a three-heat-reservoir heat pump Int J Energy Res., 1999, 23(9): 773-777 [34] Qin X, Chen L, Sun F, Wu C Thermoeconomic optimization of an endoreversible four-heatreservoir absorption-refrigerator Appl Energy, 2005, 81(4): 420-433 [35] Tao G, Chen L, Sun F Exergoeconomic performance optimization for an endoreversible simple gas turbine closed-cycle cogeneration plant Int J Ambient Energy, 2009, 30(3): 115-124 [36] Tao G, Chen L, Sun F Exergoeconomic performance optimization for an endoreversible regenerative gas turbine closed-cycle cogeneration plant Rev Mex Fis., 2009, 55(3): 192-200 [37] Sahin B, Kodal A Performance analysis of an endoreversible heat engine based on a new thermoeconomic optimization criterion Energy Convers Mgmt., 2001, 42(9): 1085-1093 [38] Sahin B, Kodal A Finite time thermoeconomic optimization for endoreversible refrigerators and heat pumps Energy Convers Mgmt., 1999, 40(9): 951-960 [39] Kodal A, Sahin B Finite time thermoeconomic optimization for irreversible heat engines Int J Thermal Sci., 2003, 42(8): 777-782 [40] Kodal A, Sahin B, Yilmaz T Effects of internal irreversibility and heat leakage on the finite time thermoeconomic performance of refrigerators and heat pumps Energy Convers Mgmt., 2000, 41(6): 607-619 [41] Kodal A, Sahin B, Ekmekci I, Yilmaz T Thermoeconomic optimization for irreversible absorption refrigerators and heat pumps Energy Convers Mgmt., 2003, 44(1): 109-123 [42] Chen L, Shen L, Sun F Performance comparison for endoreversible Carnot and Brayton heat pumps II Steady flow cycles with finite reservoirs Power System Engng., 1996, 12(5): 1-5 (in Chinese) [43] Wu C, Chen L, Sun F Optimization of steady flow heat pumps Energy Convers Mgnt., 1998, 39(5/6): 445-453 ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved 986 International Journal of Energy and Environment (IJEE), Volume 1, Issue 6, 2010, pp.969-986 [44] Bi Y, Chen L, Sun F Heating load, heating load density and COP optimizations for an endoreversible variable-temperature heat reservoir air heat pump J Energy Institute, 2009, 82(1): 43-47 [45] Bi Y, Chen L, Sun F Ecological, exergetic efficiency and heating load optimizations for irreversible variable-temperature heat reservoir simple air heat pump cycles Ind J Pure Appl Phys., 2009, 47(12): 852-862 Huijun Feng received his BS Degree from the Naval University of Engineering, P R China in 2008 He is pursuing for his MS Degree in power engineering and engineering thermophysics from Naval University of Engineering, P R China His work covers topics in finite time thermodynamics and technology support for propulsion plants He has published ten papers in the international journals Lingen Chen received all his degrees (BS, 1983; MS, 1986, PhD, 1998) in power engineering and engineering thermophysics from the Naval University of Engineering, P R China His work covers a diversity of topics in engineering thermodynamics, constructal theory, turbomachinery, reliability engineering, and technology support for propulsion plants He has been the Director of the Department of Nuclear Energy Science and Engineering and the Director of the Department of Power Engineering Now, he is the Superintendent of the Postgraduate School, Naval University of Engineering, P R China Professor Chen is the author or coauthor of over 1050 peer-refereed articles (over 460 in English journals) and nine books (two in English) E-mail address: lgchenna@yahoo.com; lingenchen@hotmail.com, Fax: 0086-27-83638709 Tel: 0086-2783615046 Fengrui Sun received his BS Degrees in 1958 in Power Engineering from the Harbing University of Technology, P R China His work covers a diversity of topics in engineering thermodynamics, constructal theory, reliability engineering, and marine nuclear reactor engineering He is a Professor in the Department of Power Engineering, Naval University of Engineering, P R China Professor Sun is the author or coauthor of over 750 peer-refereed papers (over 340 in English) and two books (one in English) ISSN 2076-2895 (Print), ISSN 2076-2909 (Online) ©2010 International Energy & Environment Foundation All rights reserved ... Conclusion Finite time exergoeconomic performance of an irreversible universal steady flow heat pump cycle model with variable-temperature heat reservoirs, and the losses of heat transfer and internal... U L = and x = y = , equations (30) and (33) become the COP and finite time exergoeconomic performance of an irreversible variable-temperature heat reservoir steady flow Otto heat pump cycle with... and y = , equations (30) and (33) become the COP and finite time exergoeconomic performance characteristics of an irreversible variable-temperature heat reservoir steady flow Dual heat pump cycle

Ngày đăng: 05/09/2013, 15:28

Tài liệu cùng người dùng

  • Đang cập nhật ...

Tài liệu liên quan