Studies of vortex breakdown and its stability in a confined cylindrical container 2

11 208 0
Studies of vortex breakdown and its stability in a confined cylindrical container 2

Đang tải... (xem toàn văn)

Tài liệu hạn chế xem trước, để xem đầy đủ mời bạn chọn Tải xuống

Thông tin tài liệu

CHAPTER DESCRIPTION OF EXPERIMENT CHAPTER DESCRIPTION OF EXPERIMENT Detailed description of the experimental set-up, instrumentation, visualization and measurement techniques employed to obtain the results in Chapters 5, and are presented in this chapter. Since a slightly different set-up was used for the results in Chapter 4, it will be introduced in that chapter. 2.1 Experimental Setup Figure 2.1 shows a schematic drawing of the overall experimental set-up. It consists of three separate systems, namely a confined cylinder with one rotating end, a flow visualization system, and a hot-film measurement system. Details of each system are explained below. Figure 2.2 presents a more detailed drawing of the confined cylinder with one rotating end. Due to extreme sensitivity of the flow to the imperfections of the test rig, much attention has been put to fabricate and assemble this part of the set-up. It consists of a Plexiglas cylinder with a matching rotating disk at the top and a stationary disk at the bottom of the cylinder, and the whole set-up sits firmly on a heavy iron table so as to reduce any unwanted vibration. The Plexiglas cylinder was fabricated from a solid piece of Plexiglas rod and painstakingly polished to optical quality to facilitate flow visualization. The resulting cylinder has an inner radius R = 8.625 ± 0.005 cm and a wall thickness of 2.1 cm. 22 CHAPTER DESCRIPTION OF EXPERIMENT Fig. 2.1 Schematic drawing of the overall experimental setup. 23 CHAPTER DESCRIPTION OF EXPERIMENT Fig. 2.2 Schematic drawing of the confined cylinder setup. On top of the cylinder, a fixed plate is push-fitted to it to ensure accurate alignment. The rotating disk is rotated on the fixed plate through a high precision thrust bearing. The edge of the rotating disk has a maximum excursion of 0.040 mm (about 0.03º) and a nominal gap of 0.40 mm between the rotating plate and the cylinder. The disk was driven by a microstepper motor operating at 20,000 steps per revolution, with an adjustable speed range of up to 240 rpm (about 25.1 rad/s). This 24 CHAPTER DESCRIPTION OF EXPERIMENT motor is controlled by a function generator with an accuracy of 0.1%. The knob of the function generator was specially modified with a fine worm-gear system so that the Reynolds number can be fine-tuned by as small as at each step (see Fig. 2.3). For the study of modulation on the rotating endwall, the motor was linked to a PC equipped with a National Instruments Real Time Digital I/O card, and controlled by a program written in Labview. The pulse train necessary to perform the required modulation was pre-calculated and sent to the motor controller through the real time I/O card during the experiments. The height H of the flow domain can be varied infinitesimally by changing the position of the stationary bottom disk using a mm pitch screw stud to give a variable aspect ratio. This unique feature of the apparatus allows incremental changes in Λ for a fixed Reynolds number, or vice versa. Fig. 2.3 A photograph of function generator with a modified knob control. 25 CHAPTER DESCRIPTION OF EXPERIMENT The working fluid was a mixture of glycerin and water with roughly 74% ~ 80% of glycerin by weight. As the viscosity of the solution for different set of experiments was slightly different, in all cases, the viscosity was measured using a Haake Rheometer. A typical kinematic viscosity (ν) of the solution of about 74% of glycerin by weight was measured to be of 0.254 ± 0.002 cm2/s at a room temperature of 22.3ºC. The temperature of the mixture was also monitored regularly using a thermocouple located at the bottom of the cylinder to the accuracy of 0.05ºC. The thermocouple was connected to a digital indicating controller to display the measured temperature with the sampling period about 0.5 seconds. Correspondingly, the uncertainty of Reynolds number is about of 0.8%. To minimize flow image distortion due to the curvature of the cylinder, the whole cylinder was immersed in a rectangular Plexiglas box filled with the same working fluid (both the solution and the Plexiglas have similar refractive indices). Due to the length of time required to run each experiment, complicated by the fact that the cylinder wall is too thick to allow efficient heat exchange between the fluid inside the cylinder and its surroundings, there is a gradual rise in the temperature of the fluid, resulting in an increase in Re at a rate ∂Re/∂t ≈ 25 per hour. For those experiments with fixed Λ and varying Re, this issue was addressed by taking note of the temperature at the time the data were collected, and the Reynolds number was then recalculated based on the relationship between viscosity and temperature obtained using a Haake Rheometer. Since the data was sampled and acquired over about 20 minutes, Re is nominally constant. For those cases with fixed Reynolds number and varying Λ, rotation rate of the top disk was re-adjusted to account for the temperature rise in order to maintain constant Re, if necessary. 26 CHAPTER DESCRIPTION OF EXPERIMENT 2.2 Flow visualization To visualize the flow, either food dye or florescent dye, which had been premixed with the working solution to achieve the same specific gravity as the working solution, was released slowly into the flow domain through a 1.5 mm diameter hole at the center of the non-rotating disk by gravity-feed method. A good control of the dye flow rate without disturbing the flow was realized by a fine-tune control valve. The food dye, which was used to view three-dimensional vortex structures, was illuminated using a fluorescent lamp, while fluorescent dye, which allowed two-dimensional (or crosssectional) viewing of the flow structure, was illuminated using a thin laser sheet (about 1.5mm) produced by directing a 5W Argon ion laser beam through a cylindrical lens (see Fig. 2.1). In all cases, the flow images were captured using Sony 3CCD color video camera (25 fames per second), which enables the analysis of the flow dynamics, as well as allowing still image to be captured via a frame grabber card in a PC. For some cases, a high resolution still digital camera was also used to obtain good quality flow visualization images. Figures 1.2 and 1.3 depicted in Chapter are typical flow visualization images captured with a digital camera using fluorescent dye and food dye (note that the photos are inverted for ease of comparison with the numerical results of others). 2.3 Cross-Correlation of Images Image cross-correlation was attempted to investigate the oscillatory behavior of the flow. Figure 2.4 shows a typical time sequence of images captured with food dye visualization for about one period time at Λ = 1.75 and Re = 2688. At this condition, the flow (dye filament) exhibits a spiral kink in the centre vortex breakdown region 27 CHAPTER DESCRIPTION OF EXPERIMENT when the recirculation bubble no longer exists (details can be referred to Chapter 5). The images of oscillation of the dye filament were recorded using a CCD camera at a rate of 25 frames per second, thus giving a temporal resolution of 1/24 s. Also, given that the flow oscillation encountered in the present investigation is less than Hz, the image acquisition rate of 25 Hz is sufficient to capture the dominant oscillating frequency (period) of the flow. Since the flow oscillation is periodic in nature, cross correlation of a sequence of images with a masking image can be used to obtain the temporal flow behavior (the dominant period of the flow). For example, it can be seen in Fig. 2.4 that the first image (t = 0s) is very similar to the last one (t = 2.333s), but is distinctively different from the other images. Thus, the cross-correlation value between the first image (considered as mask or reference image) and other images will be different. t=0s 0.333 s 0.667 s 1.000 s 1.333 s 1.667 s 2.000 s 2.333 s Fig. 2.4 Typical dye sequence of flow structures at Λ = 1.75 and Re = 2688, at times as indicated in seconds (time for the first frame is arbitrarily set to zero). The normalized cross-correlation for two images can be calculated by the following formula (see http://local.wasp.uwa.edu.au/~pbourke/other/correlate/ by Bourke). 28 CHAPTER DESCRIPTION OF EXPERIMENT i =i j = j Cr = ∑ ∑ ⎡⎣mask (i, j) − mask ⎤⎦ * ⎡⎣image(i, j) − image⎤⎦ i =i1 j = j1 i =i j = j ∑ ∑ ⎡⎣mask (i, j) − mask ⎤⎦ i =i1 j = j1 i =i j = j ∑ ∑ ⎡⎣image(i, j) − image⎤⎦ i =i1 j = j1 Where, mask(i, j) or image (i, j) is the pixel value (intensity) at (i, j) position, mask (or image ) is the averaged pixel values of the mask or the image to be sought. In present investigation, 512 video frames were used to conduct the cross-correlation analysis, with one of the frames selected as a reference (mask). Obviously, a high crosscorrelation value (maximum value of 1), indicates that the reference frame and the pattern under analysis are similar. Thus, the temporal behavior of the flow can be evaluated by the cross-correlation value with time. Figure 2.5 presents typical crosscorrelation values for a series of images (512 images) at Re = 2688 and Λ = 1.75 and its corresponding FFT analysis result, clearly showing the oscillatory state of the flow. The period obtained from this method is consistent with those predicted by numerics and hot-film measurements (details are given Chapter 5). Fig. 2.5 (a) Time series of the cross-correlation coefficient Cr of dye sequences for Re = 2688 and Λ = 1.75, with also steady state at Re = 2395 (dash line) and Re = 2660 (dot-dash line). (b) Corresponding power spectrum for Re = 2688. 29 CHAPTER DESCRIPTION OF EXPERIMENT 2.4 Hot-film Measurement Various techniques were tried to measure the oscillatory behavior of the flow, and they included particle image velocimetry (PIV), dye visualization and glue-on hotfilm. While PIV is an excellent technique to measure the overall flow field, it is not suited to measure oscillatory flow behavior as it relies on capturing flow images discretely with low frequency response. Although flow visualization combined with images cross-correlation can also be used to obtain the flow temporal behavior as shown in Section 2.3, it was found that hot-film has an added advantage, particularly in the vicinity of Hopf and Neimark-Sacker curves, where the flow exhibits long transients. Hence, hot-film measurement was used to study the temporal behavior of the flow. A Constant Temperature Anemometry (CTA) of Dantec 55 M01 was used in experiments (see Fig. 2.1). The working principle of CTA is based on the cooling effect of a flow on a heated element (or sensor), as schematically illustrated in Fig. 2.6 together with an electronic circuit for CTA. The resistance of the sensor is proportional to its temperature, thus maintaining a constant resistance of the sensor implies that its temperature must also be kept constant. If the resistance of the sensor in the Wheatstone bridge is reduced due to velocity fluctuation, this will cause the bridge to become unbalanced. Then, a feedback signal will allow a servo-amplifier to increase the bridge voltage, and hence the current through the sensor, so that the sensor is heated and the bridge balance is restored. Since the amplifier has a very high gain and the probe (sensor) is very small, the anemometer is able to respond to very rapid fluctuations in velocity. 30 CHAPTER DESCRIPTION OF EXPERIMENT R1 Sensor U – R2 R3 A + Amplifier Wheatstone bridge Fig. 2.6 Schematic of electronic circuit for constant temperature anemometer (CTA). Considering that the frequencies of interest in the present investigation are usually below Hz, a glue-on sensor (Dantec 55 R47) was chosen to minimize the interference to the flow (see Fig. 2.7). Fig. 2.7 Glue-on sensor. In experiments, two sensors were attached on the surface of the stationary end plate with water-proof glue (see Fig. 2.2). The nominal thickness of the sensor is less 0.1 mm, and therefore its effect on the flow is negligible. These two sensors were located at 2/3 of the radius of the cylinder and 180º apart. The hot-film was not calibrated 31 CHAPTER DESCRIPTION OF EXPERIMENT primarily due to the design of the glue-on hot film which makes calibration against a known flow velocity difficult; once the hot film is glued to a surface, it cannot be easily removed (without damage) for calibration in another facility. Nevertheless, calibration is not of concern when measuring the temporal frequencies in a flow. Since the frequencies of interest are below Hz, the output signal of the hot-film from the CTA (Dantec 55 M01) was conditioned by a low pass filter with a cut-off frequency of 10 Hz to eliminate high frequency noise before it was amplified with an analog amplifier. The output signal was sampled at 100 Hz using a computer for subsequent analysis. Although LDA was not attempted in the present study due to the equipment not being available in our laboratory, past studies have shown that hot-film or hot-wire anemometry is as good as or even better than LDA in term of measuring oscillatory behavior. 32 [...]... interest are below 1 Hz, the output signal of the hot-film from the CTA (Dantec 55 M01) was conditioned by a low pass filter with a cut-off frequency of 10 Hz to eliminate high frequency noise before it was amplified with an analog amplifier The output signal was sampled at 100 Hz using a computer for subsequent analysis Although LDA was not attempted in the present study due to the equipment not being available...CHAPTER 2 DESCRIPTION OF EXPERIMENT primarily due to the design of the glue-on hot film which makes calibration against a known flow velocity difficult; once the hot film is glued to a surface, it cannot be easily removed (without damage) for calibration in another facility Nevertheless, calibration is not of concern when measuring the temporal frequencies in a flow Since the frequencies of interest... computer for subsequent analysis Although LDA was not attempted in the present study due to the equipment not being available in our laboratory, past studies have shown that hot-film or hot-wire anemometry is as good as or even better than LDA in term of measuring oscillatory behavior 32 . and temperature obtained using a Haake Rheometer. Since the data was sampled and acquired over about 20 minutes, Re is nominally constant. For those cases with fixed Reynolds number and varying. fabricated from a solid piece of Plexiglas rod and painstakingly polished to optical quality to facilitate flow visualization. The resulting cylinder has an inner radius R = 8. 625 ± 0.005 cm and. efficient heat exchange between the fluid inside the cylinder and its surroundings, there is a gradual rise in the temperature of the fluid, resulting in an increase in Re at a rate ∂Re/∂t ≈ 25 per

Ngày đăng: 14/09/2015, 14:02

Từ khóa liên quan

Tài liệu cùng người dùng

Tài liệu liên quan